Laser & Optoelectronics Progress, Volume. 58, Issue 9, 0900002(2021)
Research Progress of Concentric Imaging Spectrometer with Convex Grating
[1] Li Q C, Jiang Y J[M]. Principle of spectroscopic instrument, 311-323(1999).
[2] Diner D J, Bruegge C J, Martonchik J V et al. MISR: a multiangle imaging spectroradiometer for geophysical and climatological research from Eos[J]. IEEE Transactions on Geoscience and Remote Sensing, 27, 200-214(1989).
[3] Fisher J, Antoniades J A, Rollins C et al. Hyperspectral imaging sensor for the coastal environment[J]. Proceedings of SPIE, 3482, 179-186(1998).
[4] Davis C, Bowles J, Leathers R et al. Ocean PHILLS hyperspectral imager: design, characterization, and calibration[J]. Optics Express, 10, 210-221(2002).
[5] Zheng Y Q, Yu B X. Overview of spectrum-dividing technologies in imaging spectrometers[J]. Journal of Remote Sensing, 6, 75-80(2002).
[6] Zuo B J, Zhang A H. Optical system design of the imaging spectrometer[J]. Optical Technology, 28, 187-188, 190(2002).
[7] Xue Q S. Optical system design of large relative-aperture and wide field of view spaceborne imaging spectrometer[J]. Chinese Journal of Lasers, 41, 0316003(2014).
[8] Yu F, Wen Q, Lei H J et al. Research progress in key technologies on near infrared microspectrometer[J]. Laser & Optoelectronics Progress, 55, 100003(2018).
[9] Huang L K, Wen Q, Wen Z Y et al. Micro-ultraviolet spectrometer analysis system[J]. Laser & Optoelectronics Progress, 57, 053003(2020).
[10] Rowlands N, Neville R A, Powell I P. Short-wave infrared (SWIR) imaging spectrometer for remote sensing[J]. Proceedings of SPIE, 2269, 237-247(1994).
[11] Li T H, Yang H H, Zhao Y P. Imaging spectrometer remote sensing: current status and future[J]. Remote Sensing Technology and Application, 12, 55-59(1997).
[12] Zheng Y Q, Wang H, Wang Y F. Selection and design of optical systems for spaceborne hyperspectral imagers[J]. Optics and Precision Engineering, 17, 2629-2637(2009).
[13] Wang Y M, Lang J W, Wang J Y. Status and prospect of space-borne hyperspectral imaging technology[J]. Laser & Optoelectronics Progress, 50, 010008(2013).
[14] Offner A. Unit power imaging catoptrics anastigmat[P].
[15] Mertz L. Concentric spectrographs[J]. Applied Optics, 16, 3122-3124(1977).
[16] Kwo D, Lawrence G, Chrisp M. Design of a grating spectrometer from a 1:1 Offner mirror system[J]. Proceedings of SPIE, 818, 275-281(1987).
[17] Ji Y Q, Shen W M. Design and manufacture of Offner convex grating hyper-spectral imager[J]. Infrared and Laser Engineering, 39, 285-287(2010).
[18] Zhu J C, Jin Y M, Huang X J et al. Design and optimization of broadband convex blazed grating[J]. Infrared and Laser Engineering, 46, 1120003(2017).
[19] Liu Y N, Sun D X, Hu X N et al. Development of visible and short-wave infrared hyperspectral imager onboard GF-5 satellite[J]. Journal of Remote Sensing, 24, 333-344(2020).
[20] Zheng Y Q. Design of compact Offner spectral imaging system[J]. Optics and Precision Engineering, 13, 650-657(2005).
[21] Liu W. Design and analysis of structure of compact Offner spectral imaging system[J]. Chinese Journal of Optics and Applied Optics, 3, 157-163(2010).
[22] Chrisp M P. Convex diffracting grating imaging spectrometer[P].
[23] Huang Y S, Ni Z J. Research of the concentric three-reflection optical system[J]. Optical Instruments, 27, 42-46(2005).
[24] Huang Y S, Ni Z J, Zhuang S L. Research of the concentric optical system of grating spectrometers[J]. Optical Instruments, 27, 38-42(2005).
[25] Prieto-Blanco X, Montero-Orille C, Couce B et al. Analytical design of an Offner imaging spectrometer[J]. Optics Express, 14, 9156-9168(2006).
[26] Huang Y S, Chen N S, Zhang D W et al. Design method for Offner imaging spectrometer composed of convex grating[J]. Chinese Journal of Scientific Instrument, 29, 1236-1239(2008).
[27] Tong Y J, Wu G, Zhou Q et al. Design method of Offner-type imaging spectrometer[J]. Acta Optica Sinica, 30, 1148-1152(2010).
[28] Liu G H, Wu G, Ling Q et al. Modelling of Offner imaging spectrometers and aberration analysis[J]. Acta Optica Sinica, 31, 0322001(2011).
[29] Liu Y J, Cui J C et al. Design and application of imaging spectrometer with convex grating[J]. Optics and Precision Engineering, 20, 52-57(2012).
[30] Han S, Huang Y S, Li B C et al. Theoretical analysis and research about high image quality Offner imaging spectrometer[J]. Acta Photonica Sinica, 43, 0430001(2014).
[31] Pei Z R, Huang Y S, Zhang D W et al. Research of wavelength range and spectral resolution for Offner imaging spectrometer[J]. Acta Photonica Sinica, 43, 0730004(2014).
[32] Pei Z R, Huang Y S, Ni Z J. Research of resolution for Offner two-mirror three-reflection imaging spectrometer[J]. Optical Instruments, 36, 147-151(2014).
[33] Ji Y Q, Li J X, Zhou J K et al. Analytical design and implementation of an imaging spectrometer[J]. Applied Optics, 54, 517-526(2015).
[34] Lee C M, Cable M L, Hook S J et al. An introduction to the NASA Hyperspectral InfraRed Imager (HyspIRI) mission and preparatory activities[J]. Remote Sensing of Environment, 167, 6-19(2015).
[35] Zheng Z Z, Yang Z, Qin Y T et al. Structure analysis and experiment of an Offner-type short-wave infrared imaging spectrometer[J]. Laser & Optoelectronics Progress, 57, 053001(2020).
[36] Lucke R L. Out-of-plane dispersion in an Offner spectrometer[J]. Optical Engineering, 46, 073004(2007).
[37] Prieto-Blanco X, Montero-Orille C, González-Núñez H et al. Imaging with classical spherical diffraction gratings: the quadrature configuration[J]. Journal of the Optical Society of America A, 26, 2400-2409(2009).
[38] Prieto-Blanco X, Montero-Orille C, González-Nuñez H et al. The Offner imaging spectrometer in quadrature[J]. Optics Express, 18, 12756-12769(2010).
[39] Prieto-Blanco X, González-Nuñez H, de la Fuente R. Off-plane anastigmatic imaging in Offner spectrometers[J]. Journal of the Optical Society of America A, 28, 2332-2339(2011).
[40] González-Núñez H, Prieto-Blanco X, de la Fuente R. Pupil aberrations in Offner spectrometers[J]. Journal of the Optical Society of America A, 29, 442-449(2012).
[41] Gao Z Y, Fang W, Song B Q et al. Design of off-plane Offner spectrometer with high spectral resolution[J]. Acta Optica Sinica, 36, 0211002(2016).
[42] Pan Q, Chen X H, Zhou J K et al. Manufacture of the compact conical diffraction Offner hyperspectral imaging spectrometer[J]. Applied Optics, 58, 7298-7304(2019).
[43] Wynne C G. Optical imaging systems[P].
[44] Lobb D R. Theory of concentric designs for grating spectrometers[J]. Applied Optics, 33, 2648-2658(1994).
[45] Prieto-Blanco X, de la Fuente R. Compact Offner-Wynne imaging spectrometers[J]. Optics Communications, 328, 143-150(2014).
[46] Zhang Y, Ding X Z, Yang B et al. The design of coaxial Offner thermal infrared spectrometer with WFOV[J]. Infrared Technology, 38, 537-541(2016).
[47] Zhu Y J, Yin D Y, Chen Y H et al. Design of hyperspectral resolution ultraviolet Offner imaging spectrometer system[J]. Acta Optica Sinica, 38, 0222001(2018).
[48] Zhu J C, Shen W M. Compact anastigmatic long-slit spectrometer[J]. Journal of Infrared and Millimeter Waves, 38, 542-548(2019).
[49] Zhu J C, Shen W M. Analytical design of a thermal ultra-compact concentric catadioptric imaging spectrometer[J]. Optics Express, 27, 31094-31109(2019).
[50] Lin J, Wu S, Yu L. Broadband astigmatism-free Offner imaging spectrometer with high resolution[J]. Applied Optics, 59, 1110-1116(2020).
[51] Lobb D R. Design of a spectrometer system for measurements on Earth atmosphere from geostationary orbit[J]. Proceedings of SPIE, 5249, 191-202(2004).
[52] Grange R, Milliard B, McLean R et al. Three-dimensional spectroscopy with a fiber-fed NUV spectrograph[J]. Proceedings of SPIE, 5898, 589812(2005).
[53] Whyte C, Leigh R J, Lobb D et al. Assessment of the performance of a compact concentric spectrometer system for atmospheric differential optical absorption spectroscopy[J]. Atmospheric Measurement Techniques, 2, 789-800(2009).
[55] Liu X X, Ji Y Q, He H C et al. Analysis and design of Littrow-Offner spectroscopic system[J]. Acta Optica Sinica, 33, 0422009(2013).
[56] Shen Y H, Ni Z J, Huang Y S et al. Analytical design of a high-performing +1st order diffraction convex grating imaging spectrometer[J]. Applied Optics, 59, 3760-3765(2020).
[57] Reimers J, Schiesser E M, Thompson K P et al. Comparison of freeform imaging spectrometer design forms using spectral full-field displays[C], FM3B.3(2015).
[58] Reimers J, Rolland J P. Spectral full-field displays for spectrometers[C], ITh3A.5(2014).
[59] Yang T, Zhu J, Wu X F et al. Direct design of freeform surfaces and freeform imaging systems with a point-by-point three-dimensional construction-iteration method[J]. Optics Express, 23, 10233-10246(2015).
[60] Peschel T, Damm C, Beier M et al. Design of an imaging spectrometer for Earth observation using freeform mirrors[J]. Proceedings of SPIE, 10562, 1056237(2016).
[61] Pang Z H, Fan X W, Ma Z et al. Free-form optical elements corrected aberrations of optical system[J]. Acta Optica Sinica, 36, 0522001(2016).
[62] Reimers J, Bauer A, Thompson K P et al. Freeform spectrometer enabling increased compactness[J]. Science & Applications, 6(2017).
[63] Reimers J, Thompson K P, Troutman J et al. Increased compactness of an imaging spectrometer enabled by freeform surfaces[C], JW2C.5(2017).
[64] Wei L D, Feng L, Zhou J S et al. Optical design of Offner-Chrisp imaging spectrometer with freeform surfaces[J]. Proceedings of SPIE, 10021, 100211P(2016).
[65] Marchi A Z, Borguet B. Freeform grating spectrometers for hyperspectral space applications: status of ESA programs[C], JTh2B.5(2017).
[66] Yang T, Cheng D W, Wang Y T. Freeform imaging spectrometer design using a point-by-point design method[J]. Applied Optics, 57, 4718-4727(2018).
[67] Feng L, Wei L D, Nie Y F et al. Design of a compact spectrometer with large field of view based on freeform surface[J]. Optics Communications, 444, 81-86(2019).
[68] Cao C, Liao S, Liao Z Y et al. Design of off-axis reflective optical system with large field-of-view based on freeform surfaces[J]. Acta Optica Sinica, 40, 0808001(2020).
Get Citation
Copy Citation Text
Yuhang Shen, Zhengji Ni, Yuanshen Huang, Banglian Xu, Bei Guo, Dinglu Wang. Research Progress of Concentric Imaging Spectrometer with Convex Grating[J]. Laser & Optoelectronics Progress, 2021, 58(9): 0900002
Category: Reviews
Received: Aug. 11, 2020
Accepted: Oct. 12, 2020
Published Online: May. 12, 2021
The Author Email: Ni Zhengji (sioi@usst.edu.cn)