Advanced Photonics Nexus, Volume. 2, Issue 4, 046006(2023)
Complex-domain-enhancing neural network for large-scale coherent imaging Article Video , On the Cover
Fig. 1. Architecture of the proposed CI-CDNet. (a) Complex-domain neural network architecture. (b) Complex-domain convolution operation. (c) Multisource noise model for CI.
Fig. 2. Experimental setup and resolution test of KKR holography under only 1 ms exposure time. (a) Experimental setup. CL, collimating lens; RL, relay lens; P, polarizer; BS, beam splitter; TL, tube lens; SLM, spatial light modulator. (b) Resolution test results of different enhancing methods using Siemens star under 1 ms exposure time. The blue and red curves are the cross sections of the images, which represent pixel-wise errors. The extremely short exposure time results in a low SNR of KKR direct reconstruction. (c) Running time (ms) of different enhancing methods.
Fig. 3. Quantitative results of KKR holography using a biological sample. (a) Enhancing results of different methods using a papillary thyroid carcinoma slide. (b) Quantitative results of CI-CDNet for reducing exposure time. The result of CI-CDNet under 1 ms exposure time is close to the results of KKR recovery under 50 ms exposure time (more results can be seen in Note 5 in the
Fig. 4. Results of FPM under only 0.15 ms exposure time. (a) Experimental setup. (b) Resolution test of different enhancing methods using the USAF resolution test chart under 0.15 ms exposure time. (c) Enhancing results of the unstained blood smear under 0.15 ms exposure time. (d), (e) Quantitative results (blood smear) of amplitude and phase, respectively. The proposed CI-CDNet obtains more than 11 dB (amplitude) and 18 dB (phase) improvement on the PSNR index compared with the conventional AP method. (f) Running time (s) of different enhancing methods. AP is the baseline algorithm. Other enhancing methods are regularizers in FPM reconstruction; thus their running time includes the iteration time of data-fidelity term (Note 2 in the
Fig. 5. Results of LCP. (a) Schematic diagram of LCP system. (b), (c) Reconstructed amplitude and phase of the unstained blood smear using CI-CDNet with only 50 captured images. (d) Close-ups of three ROIs. The pseudo-color part is the phase and the gray part shows the amplitude. The GT is the result of ePIE using 900 images. (e) Results of white blood cell segmentation. (f) Results of virtual staining.
|
Get Citation
Copy Citation Text
Xuyang Chang, Rifa Zhao, Shaowei Jiang, Cheng Shen, Guoan Zheng, Changhuei Yang, Liheng Bian, "Complex-domain-enhancing neural network for large-scale coherent imaging," Adv. Photon. Nexus 2, 046006 (2023)
Category: Research Articles
Received: Mar. 9, 2023
Accepted: Jun. 14, 2023
Published Online: Jul. 7, 2023
The Author Email: Bian Liheng (bian@bit.edu.cn)