Laser & Optoelectronics Progress, Volume. 56, Issue 11, 111501(2019)

Calibration of Linear Camera for Online Measurement of Lithium Battery Coating

Huaiguang Liu*, Di Wang**, Jintang Yang, and Yuanjiong Liu
Author Affiliations
  • Key Laboratory of Metallurgical Equipment and Control Technology, Wuhan University of Science and Technology, Wuhan, Hubei 430081, China
  • show less
    Figures & Tables(12)
    Schematic of coating online inspection scheme
    Diagram of coating inspection model
    Diagram of camera imaging distribution
    Diagram of camera single-dimensional imaging model
    Image calibration. (a) Left camera calibration point; (b) right camera calibration point
    LM training curves
    Contrast of calibration errors
    Field applications
    • Table 1. Camera calibration results

      View table

      Table 1. Camera calibration results

      Calibration parameterLeft cameraRight camera
      gx20.368720.3627
      tx1970.5537101.457
      Tx-104.3465-196.16979
      Calibration error0.64281.4497
    • Table 2. Camera calibration results

      View table

      Table 2. Camera calibration results

      Calibration parameterLeft cameraRight camera
      k1-2.0786×10-10-4.2328×10-11
      k22.9220×10-171.5027×10-18
      u05181.86302
      Coordinate errorafter correction0.17940.3985
    • Table 3. Characteristic point u-direction coordinates

      View table

      Table 3. Characteristic point u-direction coordinates

      Number123456789101112131415
      Xw /mm0102030405060708090100110120130140
      u /pixel102424747069381170140316361868210323372570280430383272
      Number1617181920212223242526272829
      Xw /mm150160170180190200210220230240250260270280
      u /pixel35073741397742114447468149175152538856235859609463306566
    • Table 4. Field test datamm

      View table

      Table 4. Field test datamm

      Section No.ItemB1B2B3B4B5B6B7
      1Actual value15.036172.35828.742172.76830.197171.9215.154
      Measurement error0.0380.087-0.0780.001-0.048-0.0680.019
      2Actual value15.088172.31728.799172.72730.241171.8815.115
      Measurement error0.0350.072-0.031-0.059-0.043-0.0280.009
      3Actual value15.017172.42728.672172.83230.148171.9815.1
      Measurement error0.0570.018-0.057-0.0630.001-0.0790.073
      4Actual value15.076172.32228.775172.72730.241171.915.162
      Measurement error-0.002-0.075-0.061-0.007-0.043-0.0480.011
    Tools

    Get Citation

    Copy Citation Text

    Huaiguang Liu, Di Wang, Jintang Yang, Yuanjiong Liu. Calibration of Linear Camera for Online Measurement of Lithium Battery Coating[J]. Laser & Optoelectronics Progress, 2019, 56(11): 111501

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Machine Vision

    Received: Dec. 3, 2018

    Accepted: Dec. 25, 2018

    Published Online: Jun. 13, 2019

    The Author Email: Huaiguang Liu (lhg81219@163.com), Di Wang (wangdi335566@163.com)

    DOI:10.3788/LOP56.111501

    Topics