Laser & Optoelectronics Progress, Volume. 60, Issue 6, 0628006(2023)

Development of Methane Leakage Telemetry System Based on TDLAS-WMS

Jun Xu1, Yunfei Li3,4、*, Yue Cheng3,4, Jianfei Tan4, Dong Liu2, and Zhen Zhou1
Author Affiliations
  • 1School of Electric and Information Engineering, Anhui Jianzhu University, Hefei 230601, Anhui, China
  • 2School of Mechanical and Electrical Engineering, Anhui Jianzhu University, Hefei 230601, Anhui, China
  • 3Hefei Institute of Public Safety Research, Tsinghua University, Hefei 230601, Anhui, China
  • 4Anhui Theone Safety Technology Co, Ltd., Hefei 230601, Anhui, China
  • show less
    Figures & Tables(14)
    Absorption spectra of CH4 in different ranges. (a) 5800-6800 cm-1; (b) 6040-6050 cm-1
    Overall structure design drawing of telemetry system
    Structure diagrams of methane telemetry system. (a) Optical telemetry components; (b) FPGA+ARM laser modulation, signal acquisition, processing, and demodulation embedded integrated module; (c) connection diagram of telemetry component and embedded integrated module
    Internal structure diagram of FPGA
    Flowchart of FPGA harmonic signal demodulation
    Experimental results of 1f, 2f, and 2f/1f signal value and detection distance
    System measurement of in range of 0-26000×10-6 m concentration
    Harmonic signal diagrams of different concentrations. (a) 1f signal diagram; (b) 2f signal diagram
    Change of 2f/1f peak value in the range of 0-2000×10-6 m
    2f/1f signal and concentration fitting curve
    Measurement error of different concentration
    Measurement of detection lower limit.(a) 2f signal diagram of 1500×10-6 m methane concentration; (b) noise diagram of 0×10-6 m methane concentration system
    • Table 1. System calibration experiment data

      View table

      Table 1. System calibration experiment data

      No.integral concentration /10-6 m2f/1f average amplitude /arb. units2f/1f standard deviation
      100.01150.0011
      22500.04030.0031
      34500.05330.0017
      411000.11590.0034
      518000.19810.0047
      620000.20710.0016
    • Table 2. System inversion experimental data

      View table

      Table 2. System inversion experimental data

      No.Integral concentration /10-6 mMeasured concentration /10-6 mAbsolute error /10-6 m

      Relative

      error /%

      1400399.092-0.0023-0.23
      2850839.332-10.6680-1.26
      313001258.185-41.8150-3.22
      416501589.989-60.0110-3.64
      518501782.275-67.7250-3.66
    Tools

    Get Citation

    Copy Citation Text

    Jun Xu, Yunfei Li, Yue Cheng, Jianfei Tan, Dong Liu, Zhen Zhou. Development of Methane Leakage Telemetry System Based on TDLAS-WMS[J]. Laser & Optoelectronics Progress, 2023, 60(6): 0628006

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Remote Sensing and Sensors

    Received: Dec. 23, 2021

    Accepted: Jan. 17, 2022

    Published Online: Mar. 31, 2023

    The Author Email: Yunfei Li (uc_fly@163.com)

    DOI:10.3788/LOP213323