Acta Optica Sinica, Volume. 41, Issue 4, 0411003(2021)

Research on Photonic Integrated Interferometric Imaging Mechanism and Space Spectrum Coverage

Hongliu Ma1, Kang Huang1, Yong Liu2, Hong Chang2, Shouqian Chen3, and Wang Zhang1、*
Author Affiliations
  • 1School of Mechanical and Aerospace Engineering, Jilin University, Changchun, Jilin 130025, China
  • 2Beijing Institute of Aerospace Measurement and Testing Technology, Beijing 100076, China
  • 3Research Center of Space Optics Engineering, Harbin Institute of Technology, Harbin, Heilongjiang 150001, China
  • show less
    Figures & Tables(13)
    Schematic of photonic integrated interferometric imaging system
    Schematic of interferometric imaging
    Diagram of the microlens array shape
    Uniform sampling matching method
    Schematic of the optimized photonic integrated device
    Pairing mode at the wavelength of the first part
    Pairing mode at the wavelength of the second part
    Restored images directly under different number of interference arms. (a) Original image; (b) 41; (c) 42; (d) 49; (e) 50
    Restored images directly by different interference baseline matching methods. (a) Original image; (b) new matching method; (c) matching method for collecting low frequency information intensively; (d) uniform sampling matching method; (e) matching method for collecting high frequency information intensively
    Results of direct restoration using a new interference baseline matching method. (a) Original image; (b) mutual intensity spectrum of the target image; (c) directly restored image; (d) spatial spectrum coverage
    • Table 1. PSNR and MSE under different number of interference arms

      View table

      Table 1. PSNR and MSE under different number of interference arms

      Number of interference armsPSNR/dBMSEValid number of samples
      419.83667526591
      429.56271915150
      499.86467097732
      509.74468966021
    • Table 2. [in Chinese]

      View table

      Table 2. [in Chinese]

      MethodPSNR/dBMSEValid number of samples
      Proposed pairing method9.72369296327
      Low-frequency intensive method9.43674033639
      Uniform distribution method9.43374084269
      High-frequency intensive method9.21277954289
    • Table 3. Parameters of photonic integrated interferometric imaging system

      View table

      Table 3. Parameters of photonic integrated interferometric imaging system

      ParameterSymbol of ParametersValue
      Spectral coverage wavelengthλ /nm500-900
      Microlens diameterd /mm1
      Longest baselineBmax/mm28
      Number of interference armsP39
      Number of microlens per PIC spokeN29
      Object distancez /km100
      Number of spectral binsn10
    Tools

    Get Citation

    Copy Citation Text

    Hongliu Ma, Kang Huang, Yong Liu, Hong Chang, Shouqian Chen, Wang Zhang. Research on Photonic Integrated Interferometric Imaging Mechanism and Space Spectrum Coverage[J]. Acta Optica Sinica, 2021, 41(4): 0411003

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Imaging Systems

    Received: Aug. 25, 2020

    Accepted: Oct. 9, 2020

    Published Online: Feb. 26, 2021

    The Author Email: Wang Zhang (wangzhang@jlu.edu.cn)

    DOI:10.3788/AOS202141.0411003

    Topics