Acta Optica Sinica, Volume. 34, Issue 11, 1106001(2014)
Study of Fiber Sensor for Simultaneous Measurement of Refractive and Temperature Based on a Core-Mismatch Mach-Zehnder Interferometer
[1] [1] Chen Yaofei, Han Qun, He Yang, et al.. Study of single mode-multimode-single mode refractive index sensor based on no core fiber [J]. Chinese J Lasers, 2013, 40(9): 0905001.
[2] [2] Liu Zhibo, Tan Zhongwei, Yin Bin, et al.. Refractive index sensing characterization of a singlemode-claddingless-singlemode fiber structure based fiber ring cavity laser [J]. Opt Express, 2014, 22(5): 5037-5042.
[3] [3] Ma Yue, Qiao Xueguang, Guo Tuan, et al.. Temperature-independent refractive index measurement based on Fabry-Perot fiber tip sensor modulated by Fresnel reflection [J]. Chin Opt Lett, 2012, 10(5): 050603.
[4] [4] Liao Guozhen, Zhang Jun, Cai Xiang, et al.. All-fiber temperature sensor based on grapheme [J]. Acta Optica Sinica, 2013, 33(7): 0706004.
[7] [7] Gong Yuan, Zhao Tian, Rao Yunjiang, et al.. All-fiber curvature sensor based on multimode interference [J].IEEE Phonton Technol Lett, 2011, 23(11): 679-681.
[8] [8] Yao Qiqi, Meng Hongyun, Wang Wei, et al.. Simultaneous measurement of refractive index and temperaturebased on a core-offset Mach-Zehnder interferometer combined with a fiber Bragg grating [J]. Sensors Actuators A, 2014, 209: 73-77.
[9] [9] Zhao Chunliu, Qi Liang, Zhang Shuqin, et al.. Simultaneous measurement of refractive index and temperature based on a partial cone-shaped FBG [J]. Sensors Actuators B, 2013, 178: 96-100.
[10] [10] Li Lecheng, Xia Li, Xie Zhenhua, et al.. In-line fiber Mach-Zehnder interferometer for simultaneous measurement of refractive index and temperature based on thinned fiber [J]. Sensors Actuators A, 2012, 180: 19-24.
[11] [11] Li Huidong, Fu Haiwei, Shao Min, et al.. In-fiber Mach-Zehnder interferometer based on fiber core etched air-bubble and core diameter mismatch for liquid refractive index sensing [J]. Acta Physica Sinica, 2013, 62(2): 0214209.
[12] [12] Hae Young Choi, Myoung Jin Kim, Byeong Ha Lee. All-fiber Mach-Zehnder type interferometers formed in photonic crystal fiber [J]. Opt Express, 2007, 15(9): 5711-5720.
[13] [13] Gianluca Coviello, Vittoria Finazzi, Joel Villatoro. Thermally stabilized PCF-based sensor for temperature measurements up to 1000 ℃ [J]. Opt Express, 2009, 17(24): 21551-21559.
[14] [14] Yan Jinhua, A P Zhang, Shao Liyang, et al.. Simultaneous measurement of refractive index and temperature by using dual long-period gratings with an etching process [J]. IEEE Sensors Journal, 2007, 7(9): 1360-1361.
Get Citation
Copy Citation Text
Fu Haiwei, Yan Xu, Li Huidong, Shao Min, Zhao Na, Liu Qinpeng, Gao hong, Jia Zhen′an, Qiao Xueguang. Study of Fiber Sensor for Simultaneous Measurement of Refractive and Temperature Based on a Core-Mismatch Mach-Zehnder Interferometer[J]. Acta Optica Sinica, 2014, 34(11): 1106001
Category: Fiber Optics and Optical Communications
Received: May. 20, 2014
Accepted: --
Published Online: Oct. 13, 2014
The Author Email: Haiwei Fu (hwfu@xsyu.edu.cn)