High Power Laser and Particle Beams, Volume. 34, Issue 11, 116003(2022)

Test of 100kA vacuum circuit breaker based on artificial current zero for quench protection

Xingguang Hu1,2, Jike Zhong3, Hua Li4, Hang Li2、*, and Muquan Wu2
Author Affiliations
  • 1College of Physics and Optoelectronic Engineering, Shenzhen University, Shenzhen 518061, China
  • 2Advanced Energy Research Center, Shenzhen University, Shenzhen 518060, China
  • 3Wuhan Changhai Electric Technology Development Co., Ltd, Wuhan 430073, China
  • 4Institute of Plasma Physics, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei 230031, China
  • show less
    Figures & Tables(9)
    Schematic diagram of quench protection system for CRAFT superconducting magnet
    Control logic and expected current waveform of quench protection system
    Prototype of 100 kA vacuum circuit breaker
    Topology of artificial zero crossing circuit for quench protection system
    Breaking test circuit of 100 kA vacuum circuit breaker based on artificial zero crossing
    Current breaking test site of vacuum circuit breaker
    Waveform of vacuum circuit breaker breaking 100 kA current
    • Table 1. Main parameters of interrupter for vacuum circuit breaker (BGH6210)

      View table
      View in Article

      Table 1. Main parameters of interrupter for vacuum circuit breaker (BGH6210)

      rated voltage/kVrated current/Arated short-circuit breaking current/kArated short-time withstand current/kArated short circuit duration/s
      1863001001002
    • Table 2. Component parameters of breaking test circuit

      View table
      View in Article

      Table 2. Component parameters of breaking test circuit

      capacitor of main discharge circuit C0/mF inductor of main discharge circuit L0/μH capacitor of artificial zero crossing circuit C1/mF inductor of artificial zero crossing circuit L1/μH buffer capacitor C2/mF energy dissipation resistor Rd
      86.42658.86610.125
    Tools

    Get Citation

    Copy Citation Text

    Xingguang Hu, Jike Zhong, Hua Li, Hang Li, Muquan Wu. Test of 100kA vacuum circuit breaker based on artificial current zero for quench protection[J]. High Power Laser and Particle Beams, 2022, 34(11): 116003

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Nuclear Science and Engineering

    Received: Dec. 8, 2021

    Accepted: Jun. 16, 2022

    Published Online: Oct. 18, 2022

    The Author Email: Li Hang (lih@szu.edu.cn)

    DOI:10.11884/HPLPB202234.210552