Acta Optica Sinica, Volume. 42, Issue 4, 0428001(2022)

High Sensitivity Optical Fiber Thermal Anemometer Heated by Light Source

Jiarui Zhang1,2, Dajuan Lü3, Xinyong Dong1,2、*, Pengbai Xu1,2, Jun Yang1,2, and Yuwen Qin1,2
Author Affiliations
  • 1Advanced Institute of Photonics Technology, Guangdong University of Technology, Guangzhou, Guangdong 510006, China
  • 2Guangdong Provincial Key Laboratory of Information Photonics Technology, Guangdong University of Technology, Guangzhou, Guangdong 510006, China
  • 3State Key Laboratory of Optical Fiber and Cable Manufacture Technology, Wuhan, Hubei 430073, China
  • show less
    Figures & Tables(13)
    Fiber optic anemometer probe. (a) Microscopic photograph; (b) schematic of structure
    Experimental equipment for measuring wind speed
    Interference spectra of anemometer at different temperatures
    Relationship between wavelength of anemometer and temperature
    Interference spectra of anemometer under different light source power
    Relationship among wavelength, temperature of anemometer, and power of light source
    Relationship between wavelength of anemometer and square of wind speed under power of 5 mW light source
    Response characteristics of fiber optic anemometer. (a) Interference spectra of anemometers at different wind speeds; (b) variation curves of wavelength drift and sensitivity of anemometer (cavity length is 17 μm) with wind speed
    Response curves of anemometer to wind speed under different light source power
    Response curves of anemometers with different cavity lengths to wind speed
    Dynamic response curve of anemometer (cavity length is 17 μm)
    • Table 1. Parameters and fitting degree in response curve fitting formula of anemometer to wind speed under different light source power

      View table

      Table 1. Parameters and fitting degree in response curve fitting formula of anemometer to wind speed under different light source power

      Power /mWabcR2
      601.0231-0.9154-0.00890.9984
      801.5598-1.2821-0.01140.9957
      1002.5488-1.4139-0.01860.9959
    • Table 2. Parameters and fitting degree in response curve fitting formula of anemometer to wind speed under different cavity lengths

      View table

      Table 2. Parameters and fitting degree in response curve fitting formula of anemometer to wind speed under different cavity lengths

      Length /μmabcR2
      481.3599-1.0003-0.00480.9974
      301.8538-1.0876-0.00680.9993
      172.5488-1.4139-0.01860.9959
    Tools

    Get Citation

    Copy Citation Text

    Jiarui Zhang, Dajuan Lü, Xinyong Dong, Pengbai Xu, Jun Yang, Yuwen Qin. High Sensitivity Optical Fiber Thermal Anemometer Heated by Light Source[J]. Acta Optica Sinica, 2022, 42(4): 0428001

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Remote Sensing and Sensors

    Received: Jun. 7, 2021

    Accepted: Aug. 20, 2021

    Published Online: Jan. 29, 2022

    The Author Email: Dong Xinyong (dongxy@gdut.edu.com)

    DOI:10.3788/AOS202242.0428001