Chinese Optics, Volume. 17, Issue 2, 253(2024)

Study and analysis of self-absorption-free laser-induced breakdown spectroscopy with high-repetition rate acousto-optic gating

Fei CHEN1,2, Shu-qing WANG3, Nian-kai CHENG4, Wan-fei ZHANG5, Yan ZHANG6, Jia-hui LIANG1,2, Lei ZHANG1,2、*, Gang WANG5, Xiao-fei MA5, Zhen-rong LIU5, Xue-bin LUO5, Ze-fu YE7, Zhu-jun ZHU7, Wang-bao YIN1,2、*, Lian-tuan XIAO1,2, and Suo-tang JIA1,2
Author Affiliations
  • 1State Key Laboratory of Quantum Optics and Quantum Optics Devices, Institute of Laser Spectroscopy, Shanxi University, Taiyuan 030006, China
  • 2Collaborative Innovation Center of Extreme Optics, Shanxi University, Taiyuan 030006, China
  • 3National Energy R & D Center of Petroleum Refining Technology (RIPP, SINOPEC), Beijing 100083, China
  • 4China Academy of Ordnance Science, Beijing 100089, China
  • 5Shanxi Xinhua Chemical Defense Equipment Research Institute Co., Ltd., Taiyuan 030041, China
  • 6School of Optoelectronic Engineering, Xi’an Technological University, Xi’an 710021, China
  • 7Shanxi Gemeng US-China Clean Energy R & D Center Co., Ltd, Taiyuan 030032, China
  • show less
    Figures & Tables(9)
    Experimental setup for high repetition rate acousto-optic gating SAF-LIBS (above) and principle diagram of AOM (below)
    Working time sequence scheme of the experimental setup
    Press tablet sample
    Doublet lines of Al atom at different laser repetition rates
    Linearity of calibration curves by using Al I 396.15 nm
    (a) Temporal evolutions of Al doublet intensity ratio and (b) optimal delay times and SNRs at different fiber collection angles
    (a) Doublet intensity ratio varying with delay times and (b) tot values at different aluminum contents
    (a) Calibration curves and predicted results of Al at delay times of 200 ns, 400 ns and 800 ns; (b) comparison of prediction errors of Al under different experimental conditions, the numbers 1-4 here correspond to delay of 200 ns, 400 ns, 800 ns and without AOM, respectively
    • Table 1. Aluminum content in different press tablet samples

      View table
      View in Article

      Table 1. Aluminum content in different press tablet samples

      样品编号12345678910
      占比(%)567891011131619
    Tools

    Get Citation

    Copy Citation Text

    Fei CHEN, Shu-qing WANG, Nian-kai CHENG, Wan-fei ZHANG, Yan ZHANG, Jia-hui LIANG, Lei ZHANG, Gang WANG, Xiao-fei MA, Zhen-rong LIU, Xue-bin LUO, Ze-fu YE, Zhu-jun ZHU, Wang-bao YIN, Lian-tuan XIAO, Suo-tang JIA. Study and analysis of self-absorption-free laser-induced breakdown spectroscopy with high-repetition rate acousto-optic gating[J]. Chinese Optics, 2024, 17(2): 253

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category:

    Received: Aug. 23, 2023

    Accepted: --

    Published Online: Apr. 15, 2024

    The Author Email:

    DOI:10.37188/CO.2023-0147

    Topics