Chinese Journal of Lasers, Volume. 48, Issue 15, 1517002(2021)

Modular Full-Polarization Microscope

Tongyu Huang1,2, Ruoyu Meng1, Qianhao Zhao1, Yan Leng1, Ran Liao1, Honghui He1, and Hui Ma1,2,3、*
Author Affiliations
  • 1Shenzhen International Graduate School, Tsinghua University, Shenzhen, Guangdong 518055, China
  • 2Department of Biomedical Engineering, Tsinghua University, Beijing 100084, China
  • 3Department of Physics, Tsinghua University, Beijing 100084, China
  • show less
    Figures & Tables(10)
    Schematic of transmission Mueller matrix microscope based on dual rotating retarders[24]
    Collinear reflection Mueller matrix microscope based on dual rotating retarders[16]. (a) Physical map; (b) structural diagram
    Results measured by DRR-CRMMM and oblique incident illumination reflection Mueller matrix imaging system[16]. (a)(b) Oblique incident illumination reflection Mueller matrix imaging system;(c)(d) DRR-CRMMM
    DoFP linear polarization CCD and corresponding Mueller matrix microscope. (a) Diagram of pixelated micropolarizer array of DoFP linear polarization CCD[18] ;(b) schematic of transmission Mueller matrix microscope based on dual DoFP linear polarization CCDs[22]
    Polarization parameter images of nonstained dewaxing slice of cancerous liver tissue with fibrosis in F4 stage[14]. (a) δ; (b) t; (c)θ; (d) x
    Average values of δ and t for cancerous liver tissue slice polarization parameter images in different stages [14]
    Statistical distribution histograms of θ for cancerous liver tissue slice polarization parameter images in different stages [14]
    Quantitative characterization for three distinctive pathological features (cell nuclei, aligned collagen, and disorganized collagen) in 4 different breast tissues using PFPs [35]. (a) Healthy breast tissue; (b) breast fibroma; (c) breast ductal carcinoma; (d) breast mucinous carcinoma
    Polarization parameter images of red blood cell smear[22]. (a) D; (b) αD
    • Table 1. Average acquisition time, average RMSE and condition number of three different Mueller matrix imaging methods[22]

      View table

      Table 1. Average acquisition time, average RMSE and condition number of three different Mueller matrix imaging methods[22]

      Imaging methodAcquisition time /sAverage RMSEConditional number
      Linear polarizerWave platePSGPSA
      DRR-UTMMM1920.01260.02083.6123.612
      DoFPs-UTMMM+scheme 1140.00700.00623.6772.217
      DoFPs-UTMMM+scheme 290.00690.00493.5372.217
    Tools

    Get Citation

    Copy Citation Text

    Tongyu Huang, Ruoyu Meng, Qianhao Zhao, Yan Leng, Ran Liao, Honghui He, Hui Ma. Modular Full-Polarization Microscope[J]. Chinese Journal of Lasers, 2021, 48(15): 1517002

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Special Issue: THEMED SPECIAL ISSUE FOR 110TH ANNIVERSARY OF TSINGHUA UNIVERSITY

    Received: Mar. 25, 2021

    Accepted: May. 24, 2021

    Published Online: Aug. 5, 2021

    The Author Email: Hui Ma (mahui@tsinghua.edu.cn)

    DOI:10.3788/CJL202148.1517002

    Topics