Chinese Optics Letters, Volume. 7, Issue 2, 02138(2009)

Influence of scanning velocity on bovine shank bone ablation with pulsed CO2 laser

Xianzeng Zhang, Shusen Xie, Qing Ye, and Zhenlin Zhan
Author Affiliations
  • Institute of Laser and Optoelectronics Technology, Fujian Provincial Key Laboratory for Photonics Techonology, Key Laboratory of Opto-Electronic Science and Technology for Medicine of Ministry of Education, Fujian Normal University, Fuzhou 3500072 Department of Otolaryngology, Fujian Provincial Hospital, Fuzhou 3500013 Provincial Clinical College of Fujian Medical University, Fuzhou 350001
  • show less
    References(11)

    [1] [1] J.-I. Youn, P. Sweet, and G. M. Peavy, Lasers Surg. Med. 39, 332 (2007).

    [2] [2] S. Stübinger, B. von Rechenberg, H.-F. Zeilhofer, R. Sader, and C. Landes, Lasers Surg. Med. 39, 583 (2007).

    [3] [3] J.-I. Youn, P. Sweet, G. M. Peavy, and V. Venugopalan, Lasers Surg. Med. 38, 218 (2006).

    [4] [4] J. Meister, C. Apel, R. Franzen, and N. Gutknecht, Lasers Med. Sci. 18, 112 (2003).

    [6] [6] J. Zhang and X. Zhang, Chinese J. Lasers (in Chinese) 34, 300 (2007).

    [7] [7] M. Ivanenko, R. Sader, S. Afilal, M. Werner, M. Hartstock, C. von Hanisch, S. Milz, W. Erhardt, H.-F. Zeilhofer, and P. Hering, Lasers Surg. Med. 37, 144 (2005).

    [8] [8] M. Frentzen, W. Gotz, M. Ivanenko, S. Afilal, M. Werner, and P. Hering, Lasers Med. Sci. 18, 119 (2003).

    [9] [9] M. Staninec, J. Xie, C. Q. Le, and D. Fried, Lasers Surg. Med. 33, 264 (2003).

    [10] [10] M. Ivanenko, M. Werner, S. Afilal, M. Klasing, and P. Hering, Med. Laser Appl. 20, 13 (2005).

    [11] [11] J. Meister, R. Franzen, K. Forner, H. Grebe, S. Stanzel, F. Lampert, and C. Apel, J. Biomed. Opt. 11, 034030 (2006).

    CLP Journals

    [1] Zhang Xianzeng, Wang Xiaoyan, Zhan Zhenlin, Ye Qing, Xie Shusen. Comparison of Skull Tissue Ablation with Pulse CO2 and Er:YAG Lasers[J]. Chinese Journal of Lasers, 2009, 36(10): 2577

    [2] Zhang Xianzeng, Xie Shusen, Zhan Zhenlin, Ye Qing. Advances in Hard Biotissue Ablation with Pulsed Infrared Lasers[J]. Laser & Optoelectronics Progress, 2009, 46(12): 72

    [3] Zhao Haibin, Zhang Xianzeng, Zhan Zhenlin, Xie Shusen. Influence of an Applied Water Film on Bone Hard Tissue Ablation with Pulsed CO2 Laser[J]. Chinese Journal of Lasers, 2011, 38(1): 104002

    [4] Zhan Xianzeng, Guo Jian, Zhan Zhenlin, Xie Shusen, Ye Qing. Water Spray-Assisted Ablation of Bone Hard Tissue with Pulsed CO2 Laser[J]. Acta Optica Sinica, 2010, 30(7): 2069

    [5] Liu Haishan, Zhang Xianzeng, Zhan Zhenlin, Zhao Haibin, Xie Shusen. Influence of Dynamic Focusing Conditions on Bone Hard Tissue Ablation with Pulsed CO2 Laser[J]. Laser & Optoelectronics Progress, 2012, 49(2): 21701

    Cited By
    Tools

    Get Citation

    Copy Citation Text

    Xianzeng Zhang, Shusen Xie, Qing Ye, Zhenlin Zhan, "Influence of scanning velocity on bovine shank bone ablation with pulsed CO2 laser," Chin. Opt. Lett. 7, 02138 (2009)

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Received: Jul. 15, 2008

    Accepted: --

    Published Online: Feb. 23, 2009

    The Author Email:

    DOI:10.3788/COL20090702.0138

    Topics