High Power Laser and Particle Beams, Volume. 33, Issue 4, 046002(2021)
Personal dosimeter calibration based on minitype reference radiation
[1] [1] ISO 40371: 1996, X gamma reference radiation f calibrating dosemeters doserate meters f determining their response as a function of photon energy—Part 1: Radiation acteristics production methods[S].
[2] [2] ISO 40372: 1997, X gamma reference radiation f calibrating dosemeters doserate meters f determining their response as a function of photon energy—Part 2: Dosimetry f radiation protection over the energy ranges 8 keV to 1.3 MeV 4 MeV to 9 MeV[S].
[3] [3] ISO 40373: 1999, X gamma reference radiation f calibrating dosemeters doserate meters f determining their response as a function of photon energy—Part 3: Calibration of area personal dosemeters the measurement of their response as a function of energy angle of incidence[S].
[4] [4] ISO 40374: 2004, X gamma reference radiation f calibrating dosemeters doserate meters f determining their response as a function of photon energy—Part 4: Calibration of area personal dosemeters in low energy X reference radiation fields[S].
[5] Leitner A, Witzani J, Boutillon M, et al. International comparisons of air kerma standards in 137Cs gamma radiation[J]. Metrologia, 34, 169(1997).
[6] [6] AllisyRoberts P J, Burns D T, Takata N, et al. Comparison of the stards f air kerma of the NMIJ the BIPM f 137Cs γ rays[R]. Rappt International Bureau of Weights Measures, 2004, 12: 18.
[7] Allisy-Roberts P J, Kessler C, Burns D T, et al. Comparison of the standards for air kerma of the LNE-LNHB and the BIPM for 137Cs gamma radiation[J]. Metrologia, 46, P06011(2009).
[8] Kessler C, Roger P, Allisy-Roberts P J, et al. Comparison of standards for air kerma of the KRISS and the BIPM for 137Cs gamma radiation[J]. Metrologia, 47, P06022(2010).
[9] Kessler C, Allisy-Roberts P J, Burns D T, et al. Comparison of the standards for air kerma of the ITN (Portugal) and the BIPM for 137Cs γ-rays[J]. Metrologia, 47, P06007(2009).
[10] Liu Yixin, Wei Biao, Zhuo Renhong, et al. Determination of the conventional true value of gamma-ray air kerma in a minitype reference radiation[J]. Applied Radiation and Isotopes, 118, 238-245(2016).
[11] Liu Yixin, Wei Biao, Xu Yang, et al. Feasibility study on determining the conventional true value of gamma-ray air kerma in a minitype reference radiation[J]. Nuclear Science and Techniques, 28, 3-7(2017).
[13] Li Wenjie, Liu Yixin, Wei Biao, et al. Monte Carlo simulation investigation on the minitype reference radiation employed for the calibration of gamma ray dose or dose rate meters[J]. Journal of Radiological Protection, 38, 407-421(2018).
[14] [14] IEC 61526: 2010, Radiation protection instrumentation—Measurement of personal dose equivalents Hp(10) Hp(0.07) f X, gamma, neutron beta radiations—Direct reading personal dose equivalent meters[S].
Get Citation
Copy Citation Text
Yikun Qian, Peng Feng, Yixin Liu, Yadi Zhu, Yuchen Huang, Song Zhang, Peng He, Biao Wei, Benjiang Mao. Personal dosimeter calibration based on minitype reference radiation[J]. High Power Laser and Particle Beams, 2021, 33(4): 046002
Category: Nuclear Science and Engineering
Received: Oct. 11, 2020
Accepted: --
Published Online: Jun. 24, 2021
The Author Email: Mao Benjiang (gena@vip.sina.com)