Optics and Precision Engineering, Volume. 31, Issue 17, 2546(2023)

Calibration of piezoelectric three-dimensional force sensor considering angle deviation

Jun ZHANG*... Yuhe WANG, Zongjin REN, Wenju SUN and Jiale CAI |Show fewer author(s)
Author Affiliations
  • College of Mechanical Engineering, Dalian University of Technology, Dalian116024, China
  • show less
    Figures & Tables(16)
    Piezoelectric sensor and preload calibration structure
    Sources of calibration angle deviation
    Measurement of sensor angle and base angle
    Deflection measurement of calibration force source
    Equipment for calibration of force sensor
    Parameter solving iterative process
    Decoupling error comparison
    Proportion analysis of coupling coefficients
    • Table 1. Angle deviation measurement

      View table
      View in Article

      Table 1. Angle deviation measurement

      DeviationAngle
      x+0.008 7
      y-0.007 0
      z+0.003 8
      θxy0
      θxz+0.008 7
      θyx-0.002 3
      θyz+0.015 0
      θzx-0.002 6
      θzy-0.005 2
    • Table 2. X-directional load output data

      View table
      View in Article

      Table 2. X-directional load output data

      Load/NX/mVY/mVZ/mV
      300-315.86-5.785.49
      600-628.69-13.6414.24
      900-942.93-18.0524.07
      1 200-1 256.50-23.0534.60
      1 500-1 568.16-28.2845.72
      1 800-1 880.08-33.3256.58
      2 100-2 193.72-38.9567.24
      2 400-2 507.73-44.5276.88
    • Table 3. Y-directional load output data

      View table
      View in Article

      Table 3. Y-directional load output data

      Load/NX/mVY/mVZ/mV
      3000.44-309.00-2.75
      6002.52-617.175.75
      9004.23-924.8610.57
      1 2005.44-1 233.406.85
      1 5005.92-1 539.612.79
      1 8007.71-1 846.670.79
      2 1008.75-2 154.36-0.02
      2 4008.85-2 463.11-2.72
    • Table 4. Z-directional load output data

      View table
      View in Article

      Table 4. Z-directional load output data

      Load/NX/mVY/mVZ/mV
      1 500-23.57-6.75-1 414.92
      3 000-45.01-20.47-2 832.30
      4 500-58.29-25.03-4 242.38
      6 000-65.26-25.96-5 650.50
      7 500-74.23-26.50-7 062.47
      9 000-81.68-27.28-8 461.86
      10 500-88.18-27.63-9 872.06
      12 000-96.05-24.78-11 277.35
    • Table 5. Comparison of coupling coefficients

      View table
      View in Article

      Table 5. Comparison of coupling coefficients

      Methodkyxkzxkxykzykxzkyz
      Old model0.004 0-0.006 4-0.017 8-0.001 30.034 7-0.002 5
      New model0.000 1-0.006 6-0.016 90.004 300.036 00.005 2
    • Table 6. Comparison of main direction coefficients

      View table
      View in Article

      Table 6. Comparison of main direction coefficients

      Methodkxxkyykzz
      Old model-1.043 3-1.025 3-0.938 9
      New model-1.044 9-1.026 4-0.941 1
    • Table 7. Decoupling error mean reduction ratio

      View table
      View in Article

      Table 7. Decoupling error mean reduction ratio

      DirectionX loadY loadZ load
      X output79078
      Y output818080
      Z output808181
    • Table 8. Decoupling error peak reduction ratio

      View table
      View in Article

      Table 8. Decoupling error peak reduction ratio

      DirectionX loadY loadZ load
      X output49040
      Y output204340
      Z output392549
    Tools

    Get Citation

    Copy Citation Text

    Jun ZHANG, Yuhe WANG, Zongjin REN, Wenju SUN, Jiale CAI. Calibration of piezoelectric three-dimensional force sensor considering angle deviation[J]. Optics and Precision Engineering, 2023, 31(17): 2546

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Micro/Nano Technology and Fine Mechanics

    Received: Feb. 22, 2023

    Accepted: --

    Published Online: Oct. 9, 2023

    The Author Email: ZHANG Jun (zhangj@dlut.edu.cn)

    DOI:10.37188/OPE.20233117.2546

    Topics