Optics and Precision Engineering, Volume. 32, Issue 14, 2225(2024)

Optimized precision temperature control method and experimental validation for non-uniform discontinuous X-ray telescope

Xiaofeng ZHANG1... Jianchao FENG1, Jia MA2, Xing LIAO1, Yonghe ZHANG1,* and Yong CHEN2 |Show fewer author(s)
Author Affiliations
  • 1Innovation Academy for Microsatellites of Chinese Academy of Sciences, Shanghai20203, China
  • 2Institute of High Energy Physics, Chinese Academy of Sciences, Beijing100049, China
  • show less
    Figures & Tables(11)
    Diagram of X-ray telescope system components and heat transfer model
    Lens parameters (lens thickness δ, diameter D, contact heat transfer coefficient G0)
    Analysis of focused lens heat transfer factor and expected value of spoke thermal compensation (Gr is the radiative heat transfer factor G4 1,G5 1 between the lens and the radial environment Tr, and Gd is the radiative heat transfer factor G6 1,G7 1 between the axial environment Td)
    Spoke area heat exchanger grid division
    Analysis flow of the optimal design method for the first type of heater
    Curve of variation of surrogate value with the number of regions (at k=4, the surrogate value is minimized to 0.283 4)
    Assembly status of two types of heaters on a focusing mirror hub
    Schematic diagram of the overall distribution of the two types of heaters (a-1 to a-16 for type I heaters, b-1 to b-16 for type II heaters)
    Distribution of thermocouples on the lens
    Results of lens temperature test
    • Table 1. Minimum deviation and segmentation results for different number of regions

      View table
      View in Article

      Table 1. Minimum deviation and segmentation results for different number of regions

      区域数镜片编号区间功率/W均值偏差e1/℃最大偏差e2/℃
      11, 54]0.6334.6797.047
      215],[6, 54]0.284,0.3481.0101.634
      315],[6, 17],[18, 54]0.284,0.186,0.1620.3370.565
      415],[6, 17],[18, 29],[30, 54]0.284,0.186,0.099,0.0630.2390.572
      515],[6, 17],[18, 29],[30, 39],[40, 54]0.284,0.186,0.099,0.046,0.0180.2000.574
      615],[613],[14, 17],[18, 29],[30, 39],[40, 54]0.284,0.142,0.044,0.099,0.046,0.0180.1670.577
      715],[613],[14, 17],[18, 21],[22, 29],[30, 39],[40, 54]0.284,0.142,0.044,0.04,0.058,0.046,0.0180.1520.579
    Tools

    Get Citation

    Copy Citation Text

    Xiaofeng ZHANG, Jianchao FENG, Jia MA, Xing LIAO, Yonghe ZHANG, Yong CHEN. Optimized precision temperature control method and experimental validation for non-uniform discontinuous X-ray telescope[J]. Optics and Precision Engineering, 2024, 32(14): 2225

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category:

    Received: Apr. 17, 2024

    Accepted: --

    Published Online: Sep. 27, 2024

    The Author Email: ZHANG Yonghe (zhangyh@microsate.com)

    DOI:10.37188/OPE.20243214.2225

    Topics