Optics and Precision Engineering, Volume. 29, Issue 11, 2603(2021)

Kinematics model of articulated arm measuring machine

Lian-dong YU1...2, Jia-ming CAO1,2, Hui-ning ZHAO1,2,*, Hua-kun JIA1,2, and Song PU12 |Show fewer author(s)
Author Affiliations
  • 1School of Instrument Science and Opto-electronics Engineering, Hefei University of Technology, Hefei230009, China
  • 2Anhui Province Key Laboratory of Measuring Theory and Precision Instrument, Hefei30009, China
  • show less
    References(22)

    [1] [1] 1于连栋, 赵会宁. 关节类坐标测量机关键技术及进展[J]. 仪器仪表学报, 2017, 38(8): 1879-1888. doi: 10.3969/j.issn.0254-3087.2017.08.006YUL D, ZHAOH N. Key technologies and advances of articulated coordinate measuring machines[J]. Chinese Journal of Scientific Instrument, 2017, 38(8): 1879-1888. (in Chinese). doi: 10.3969/j.issn.0254-3087.2017.08.006

    [2] Y B LI, T J LI, H F ZHU et al. Comparative analysis of the kinematics solution based on the DH method and screw theory. Mathematical Problems in Engineering, 2021, 1-13(2021).

    [3] S A HAYATI. Robot arm geometric link parameter estimation, 1477-1483(1983).

    [4] W K VEITSCHEGGER, C H WU. Robot calibration and compensation. IEEE Journal on Robotics and Automation, 4, 643-656(1988).

    [5] H ZHUANG, Z S ROTH. A linear solution to the kinematic parameter identification of robot manipulators. IEEE Transactions on Robotics and Automation, 9, 174-185(1993).

    [6] R B HE, X W LI, T L SHI et al. A kinematic calibration method based on the product of exponentials formula for serial robot using position measurements. Robotica, 33, 1295-1313(2015).

    [7] H LIU, W D ZHU, H Y DONG et al. An improved kinematic model for serial robot calibration based on local POE formula using position measurement. Industrial Robot: an International Journal, 45, 573-584(2018).

    [8] H N ZHAO, L D YU, H K JIA et al. A new kinematic model of portable articulated coordinate measuring machine. Applied Sciences, 6, 181(2016).

    [9] Y Z JIANG, L D YU, H K JIA et al. Absolute positioning accuracy improvement in an industrial robot. Sensors, 20, 4354(2020).

    [10] X G FENG, J Q ZHU, J Y ZHANG. The length error compensation method of articulated arm coordinate measuring machine. Review of Scientific Instruments, 90, 105106(2019).

    [11] [11] 11GJB1801-93,方法101 倾角回转误差试验:惯性技术测试设备主要性能试验方法[S].国防科学技术工业委员会,1993. doi: 10.15385/yb.miracle.1993GJB1801-93, Method 101 Tilt angle rotation error test:Testing methods of major performance for test equipments of inertial technology[S]. National Defense Science, technology and Industry Commission, 1993. (in Chinese). doi: 10.15385/yb.miracle.1993

    [12] [12] 12霍炎, 任顺清. 轴系倾角回转误差中一次谐振的分离方法[J]. 哈尔滨工业大学学报, 2017, 49(10): 83-89. doi: 10.11918/j.issn.0367-6234.201605118HUOY, RENSH Q. Error separation technology of the first harmonic resonance from the angular rotation errors[J]. Journal of Harbin Institute of Technology, 2017, 49(10): 83-89. (in Chinese). doi: 10.11918/j.issn.0367-6234.201605118

    [13] C C BAO, J K LI, Q B FENG et al. Error-compensation model for simultaneous measurement of five degrees of freedom motion errors of a rotary axis. Measurement Science and Technology, 29(2018).

    [14] R E BRIDGES, R SULLIVAN et al. Apparatus and method to compensate bearing runout in an articulated arm coordinate measurement machine.

    [15] C RAKSIRI, K PA-IM, S RODKWAN. An analysis of joint assembly geometric errors affecting end-effector for six-axis robots. Robotics, 9, 27(2020).

    [16] [16] 16张滋黎, 朱涵, 周维虎. 激光跟踪仪转镜倾斜误差的标定及修正[J]. 光学 精密工程, 2015, 23(5): 1205-1212. doi: 10.3788/OPE.20152305.1205ZHANGZ L, ZHUH, ZHOUW H. Error calibration and correction of mirror tilt in laser trackers[J]. Opt. Precision Eng., 2015, 23(5): 1205-1212. (in Chinese). doi: 10.3788/OPE.20152305.1205

    [17] H K JIA, L D YU, H N ZHAO et al. A new method of angle measurement error analysis of rotary encoders. Applied Sciences, 9, 3415(2019).

    [18] [18] 18许允斗, 王超, 赵春霖, 等. 2RPU/UPR+RP五自由度混联机器人参数标定研究[J]. 光学 精密工程, 2020, 28(1): 119-129. doi: 10.3788/ope.20202801.0119XUY D, WANGCH, ZHAOCH L, et al. Parameter calibration of five-degree-of-freedom hybrid robot 2RPU/UPR+RP[J]. Opt. Precision Eng., 2020, 28(1): 119-129. (in Chinese). doi: 10.3788/ope.20202801.0119

    [19] [19] 19杨聚庆, 王大勇, 董登峰, 等. 激光测量标定机器人坐标系位姿变换的正交化解算[J]. 光学 精密工程, 2018, 26(8): 1985-1993. doi: 10.3788/OPE.20182608.1985YANGJ Q, WANGD Y, DONGD F, et al. Laser measurement based evaluation for orthogonal transformation calibration of robot pose[J]. Opt. Precision Eng., 2018, 26(8): 1985-1993. (in Chinese). doi: 10.3788/OPE.20182608.1985

    [20] [20] 20汪平平. 柔性坐标测量机精度理论及应用技术研究[D]. 合肥:合肥工业大学,2006. doi: 10.1117/12.716193WANGP P. Research on Precision Theory and Application Technology of Flexible Coordinate Measuring Machine[D]. Hefei:Hefei University of Technology, 2006. (in Chinese). doi: 10.1117/12.716193

    [21] SEL ASMAI, F HENNEBELLE, T COOREVITS et al. Proposition of a periodic verification test for Articulated Arm Coordinate Measuring Machines using a small 3D artefact. Measurement, 154, 107472(2020).

    [22] H N ZHAO, L D YU, J M CAO et al. Improving the measuring length accuracy of articulated arm coordinate measuring machine using artificial neural network. Review of Scientific Instruments, 91, 125106(2020).

    Tools

    Get Citation

    Copy Citation Text

    Lian-dong YU, Jia-ming CAO, Hui-ning ZHAO, Hua-kun JIA, Song PU. Kinematics model of articulated arm measuring machine[J]. Optics and Precision Engineering, 2021, 29(11): 2603

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Micro/Nano Technology and Fine Mechanics

    Received: Mar. 25, 2021

    Accepted: --

    Published Online: Dec. 10, 2021

    The Author Email: ZHAO Hui-ning (hnzhao@mail.hfut.edu.cn)

    DOI:10.37188/OPE.20212911.2603

    Topics