Opto-Electronic Engineering, Volume. 51, Issue 7, 240113(2024)

Research on high-precision dynamic focus detection technology of differential critical angle method

Lingna Peng1...2, Yuanyuan Zhao1,2, Yang Zhang1,2, and Xuanming Duan12,* |Show fewer author(s)
Author Affiliations
  • 1Guangdong Provincial Key Laboratory of Optical Fiber Sensing and Communications, Institute of Photonics Technology, Jinan University, Guangzhou, Guangdong 511443, China
  • 2School of Physics and Optoelectronic Engineering, Jinan University, Guangzhou, Guangdong 510632, China
  • show less

    Based on the characteristics of low light energy loss, relatively simple assembly, relatively easy debugging, and high system resolution, the critical angle focusing technology can be introduced to amplify the extracted focusing signal, improve the detection sensitivity and the smoothness of the focusing curve, and at the same time achieve a larger focal plane detection range, reducing the focusing error affected by the unevenness of the substrate itself. This paper first starts from the basic principle of the differential critical angle focusing technology and obtains the relationship between the defocus amount and the defocus signal through the Fresnel formula and the Newton formula. Secondly, a differential critical angle focusing verification system is built, a four-quadrant photodetector collects the defocus signal of a single critical angle prism, and the defocus signals received by two vertically placed four-quadrant photodetectors are differentially calculated to obtain the relationship between the differential K value and the defocus amount z. The experimental results show that when a wavelength of 532 nm laser and a numerical aperture of 0.3 projection objective are used, the focusing linear range can reach 22 μm. When a numerical aperture of 0.45 projection objective is used, the focusing linear range can reach 14 μm, and the resolution of the differential critical angle focusing method can reach 25 nm.

    Keywords
    Tools

    Get Citation

    Copy Citation Text

    Lingna Peng, Yuanyuan Zhao, Yang Zhang, Xuanming Duan. Research on high-precision dynamic focus detection technology of differential critical angle method[J]. Opto-Electronic Engineering, 2024, 51(7): 240113

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Article

    Received: May. 14, 2024

    Accepted: Jun. 21, 2024

    Published Online: Nov. 12, 2024

    The Author Email: Duan Xuanming (段宣明)

    DOI:10.12086/oee.2024.240113

    Topics