Journal of Radiation Research and Radiation Processing, Volume. 42, Issue 4, 040702(2024)

Tissue equivalent conversion of microdosimeters by Fourier transform

Songke YU1... Dong WANG2 and Julan XIAO1,* |Show fewer author(s)
Author Affiliations
  • 1School of Electronic Engineering, Chengdu Technological University, Chengdu 611730, China
  • 2China Nuclear Power Technology Research Institute, Shenzhen 518000, China
  • show less
    References(12)

    [1] Rossi H H, Zaider M[M]. Microdosimetry and its applications(1996).

    [2] Rosenfeld A B. Novel detectors for silicon based microdosimetry, their concepts and applications[J]. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 809, 156-170(2016).

    [3] Davis J A, Petasecca M, Guatelli S et al. Evolution of Diamond based Microdosimetry[J]. Journal of Physics: Conference Series, 1154, 012007(2019).

    [4] Yu S K, Wang D, Zhong X J et al. A theoretical comparison of silicon and diamond in microdosimetry[J]. Journal of Instrumentation, 18, P01032(2023).

    [5] Davis J A, Guatelli S, Petasecca M et al. Tissue equivalence study of a novel diamond-based microdosimeter for galactic cosmic rays and solar particle events[J]. IEEE Transactions on Nuclear Science, 61, 1544-1551(2014).

    [6] Davis J A, Lazarakis P, Vohradsky J et al. Tissue equivalence of diamond for heavy charged particles[J]. Radiation Measurements, 122, 1-9(2019).

    [7] Bolst D, Guatelli S, Tran L T et al. Correction factors to convert microdosimetry measurements in silicon to tissue in 12C ion therapy[J]. Physics in Medicine and Biology, 62, 2055-2069(2017).

    [8] Davis J A. Diamond microdosimetry for radioprotection applications in space[D](2015).

    [10] McParland B J[M]. Medical radiation dosimetry(2014).

    [11] Sigmund P[M]. Particle penetration and radiation effects(2006).

    [12] YU Songke, XIE Zhenjian, TANG Lin et al. The experiment design of solid-state microdosimeter tissue equivalence conversion[J]. Experimental Technology and Management, 40, 170-174(2023).

    [13] Yu S K, Fan W J, Tang L et al. A method for converting microdosimetric spectra in diamond to tissue in proton therapy[J]. Medical Physics, 49, 4743-4754(2022).

    Tools

    Get Citation

    Copy Citation Text

    Songke YU, Dong WANG, Julan XIAO. Tissue equivalent conversion of microdosimeters by Fourier transform[J]. Journal of Radiation Research and Radiation Processing, 2024, 42(4): 040702

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: RADIATION INTERDISCIPLINARY RESEARCH

    Received: Apr. 8, 2024

    Accepted: May. 13, 2024

    Published Online: Sep. 14, 2024

    The Author Email: Julan XIAO (肖菊兰)

    DOI:10.11889/j.1000-3436.2024-0030

    Topics