Journal of Radiation Research and Radiation Processing, Volume. 42, Issue 4, 040702(2024)

Tissue equivalent conversion of microdosimeters by Fourier transform

Songke YU1... Dong WANG2 and Julan XIAO1,* |Show fewer author(s)
Author Affiliations
  • 1School of Electronic Engineering, Chengdu Technological University, Chengdu 611730, China
  • 2China Nuclear Power Technology Research Institute, Shenzhen 518000, China
  • show less
    Figures & Tables(7)
    Stopping power ratio of diamond and water in the proton radiation field[9]
    Schematic demonstration of the energy deposition in adjacent targets
    Comparison between spectra converted from diamond to tissue and that in tissue
    • Table 1. The size of diamond and water in the tissue equivalence conversion test

      View table
      View in Article

      Table 1. The size of diamond and water in the tissue equivalence conversion test

      材料

      Material

      金刚石/水体

      Diamond/water

      编号

      Number

      123456

      立方体边长 / μm

      Side length

      510255075100
    • Table 2. Scaling factors for different sizes in the tissue equivalence conversion test

      View table
      View in Article

      Table 2. Scaling factors for different sizes in the tissue equivalence conversion test

      编号

      Number

      123456

      换算系数

      Scaling factors

      3.153.163.183.213.253.29
    • Table 3. Pearson correlation coefficients between conversion results and spectra in tissue

      View table
      View in Article

      Table 3. Pearson correlation coefficients between conversion results and spectra in tissue

      编号

      Number

      123456

      皮尔逊相关系数

      Pearson coefficients

      0.912 70.949 10.977 90.998 60.998 40.998 0
    • Table 4. The κvalue for different sizes at 10 MeV proton beams irradiation

      View table
      View in Article

      Table 4. The κvalue for different sizes at 10 MeV proton beams irradiation

      κ系数 κvalue

      编号

      Number

      123456

      金刚石

      Diamond

      0.290.591.472.944.415.87

      水体

      Water

      0.090.190.460.931.391.86
    Tools

    Get Citation

    Copy Citation Text

    Songke YU, Dong WANG, Julan XIAO. Tissue equivalent conversion of microdosimeters by Fourier transform[J]. Journal of Radiation Research and Radiation Processing, 2024, 42(4): 040702

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: RADIATION INTERDISCIPLINARY RESEARCH

    Received: Apr. 8, 2024

    Accepted: May. 13, 2024

    Published Online: Sep. 14, 2024

    The Author Email: XIAO Julan (肖菊兰)

    DOI:10.11889/j.1000-3436.2024-0030

    Topics