Infrared and Laser Engineering, Volume. 53, Issue 12, 20240426(2024)

Research on vacuum ultraviolet spectral responsivity calibration device based on synchrotron radiation

Hao YANG1, Chunlian ZHAN1, Guangwei SUN2, Zhouhong ZHU1、*, Jiapeng WANG2, Jidong DU2, Guoao ZHOU2, and Kui JIANG2
Author Affiliations
  • 1College of Optical and Electronic Technology, China Jiliang University, Hangzhou 310018, China
  • 2Beijing Zhenxing Institute of Metrology and Testing, Beijing 100074, China
  • show less
    References(15)

    [1] Yongyou GENG, Changmeng DENG, Yiqun WU. Recent progress of extreme ultraviolet resists. Infrared and Laser Engineering, 43, 1850-1856(2014).

    [2] Shiya SUN, Fuxiang Huang, Xueqi. Xia. Forward simulation of solar backscattered ultraviolet radiation for satellite over the Tibetan plateau. Optical Precision Engineering, 30, 256-263(2022).

    [3] Yufeng ZHANG, Hongjie WANG, Yonghong ZHU et al. Research on mars camera. Infrared and Laser Engineering, 45, 209-215(2016).

    [4] Han LI, Hongsheng SUN, Jiapeng WANG et al. Calibration device for UV radiation celestial body simulator. Infrared and Laser Engineering, 43, 1568-1573(2014).

    [5] [5] Xiong Limin, Lin Yong, Fan, Qiming, et al. Research onm easurement methods f spectral responsivity of photodetects in the UV b (200400 nm) [C]Proceedings of the Academic Symposium on Radiation Metrology by the Chinese Society f Metrology Testing, 2006, 2006: 241246.

    [6] Yinghang CHEN, Zuoning SUI, Hongsheng SUN et al. Facility for calibration of ultraviolet and vacuumultraviolet spectral irradiance. Infrared and Laser Engineering, 42, 998-1002(2013).

    [8] Chunlian ZHAN, Yanmei LI, Jianping LIU et al. The unitormity and linearity of infrared spectral response of detector. Journal of Applied Optics, 25, 34-37(2004).

    [10] Zhike QUAN, Yesheng GAO, Hengfei WANG. The measurement for the photo-detector's absolute spectral responsivity based on the cryogenic radiometer. Journal of Astronautic Metrology and Measurement, 29, 70-72(2009).

    [11] Ji WANG, Xiaobing Zheng, Lei Zhang, . et al. Measurement of spectral responsivity of an infrared detector. Journal of Applied Optics, 28, 313-316(2007).

    [12] Gangwei SUN, Jidong DU, Shiwei LI et al. Calibration device for key parameters of VUV detector. Journal of Astronautic Metrology and Measurement, 42, 23-28(2022).

    [13] L BÜERMANN, B GROSSWENDT. Measurement of thex-ray mass energy-absorption coefficient of air using 3 keV to 10 keV synchrotron radiation. Physics inMedicine & Biology, 51, 5125(2006).

    [14] Hongsheng SUN, Guangwei SUN, Jiapeng WANG. et al. Research on calibration technology for UV-vacuum ultraviolet imaging spectrometer. Journal of Applied Optics, 778-785(2020).

    [15] Jinyuan LIU, XUE, Fengyi, Ping LI et al. Detector calibration facility in the wavelength range of VUV soft X-Ray(5-105 nm). Acta Metrologica Sinica, 275-279(2008).

    Tools

    Get Citation

    Copy Citation Text

    Hao YANG, Chunlian ZHAN, Guangwei SUN, Zhouhong ZHU, Jiapeng WANG, Jidong DU, Guoao ZHOU, Kui JIANG. Research on vacuum ultraviolet spectral responsivity calibration device based on synchrotron radiation[J]. Infrared and Laser Engineering, 2024, 53(12): 20240426

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: 光电测量

    Received: Sep. 21, 2024

    Accepted: --

    Published Online: Jan. 16, 2025

    The Author Email: ZHU Zhouhong (181615904@qq.com)

    DOI:10.3788/IRLA20240426

    Topics