Journal of Terahertz Science and Electronic Information Technology , Volume. 18, Issue 5, 951(2020)

Nondestructive testing of MCS dielectric defect based on A-Scan and C-Scan of Ultrasonic Test

HE Zhigang, LIANG Dongcheng, GONG Guohu, and WANG Xiaomin*
Author Affiliations
  • [in Chinese]
  • show less

    Ultrasonic Test(UT) technology for dielectric defects of Multilayer Ceramic Structure(MCS) is studied. Firstly, UT is proved to be applicable and effective to voids and delamination through thin layer reflections theoretical calculating on Multi-Layer Ceramic Capacitors(MLCC) structure, as low UT frequency can get very strong reflection signal at extremely thin aperture. Simultaneously, suggestion of C-Scan testing parameters including equivalent focal length, surface wave time, data gate and gain is given. Then, the practical UT test of MCS indicates that 50 MHz is the optimum screening frequency. Finally, defect determining and locating is accomplished via A-Scan and transit time respectively, the conclusion is also verified by sectioned UT sample preparation and detection.

    Tools

    Get Citation

    Copy Citation Text

    HE Zhigang, LIANG Dongcheng, GONG Guohu, WANG Xiaomin. Nondestructive testing of MCS dielectric defect based on A-Scan and C-Scan of Ultrasonic Test[J]. Journal of Terahertz Science and Electronic Information Technology , 2020, 18(5): 951

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category:

    Received: Feb. 23, 2019

    Accepted: --

    Published Online: Jan. 22, 2021

    The Author Email: Xiaomin WANG (wangxm005@sina.com)

    DOI:10.11805/tkyda2019052

    Topics