Infrared and Laser Engineering, Volume. 49, Issue 4, 0413006(2020)

Integrated imaging system of eye axis and anterior segment based on SS-OCT

Huaiyu Cai1... Weiqian Zhang1, Xiaoyan Han1, Yi Wang1, Wenguang Chen2 and Xiaodong Chen1 |Show fewer author(s)
Author Affiliations
  • 1Key Laboratory of Opto-Electronics Information Technology of Ministry of Education, College of Precision Instrument and Opto-Electronic Engineering, Tianjin University, Tianjin 300072, China
  • 2Shanghai Medi Works Precision Instrument Incorporated Company, Shanghai 200237, China
  • show less
    References(28)

    [2] Y Wang, L Feng, L Zhu. Measurement of ocular axial length using full-range spectral-domain low-coherence interferometry. Chinese Optics Letters, 16, 1-5(2018).

    [4] W D Lee, K Devarajan, J Chua. Optical coherence tomography angiography for the anterior segment. Eye and Vision, 6, 1-9(2019).

    [5] Tongda Wei, Yunhai Zhang, Haomin Yang. Super resolution imaging technology of stimulated emission depletion. Infrared and Laser Engineering, 45, 0624001(2016).

    [6] Jianying Zhang, Wenming Xie, Zhiping Zeng. Recent progress in photoacoustic imaging technology. Chinese Journal of Optics, 4, 111-117(2011).

    [7] M Muzyka-Woźniak, A Oleszko. Comparison of anterior segment parameters and axial length measurements performed on a Scheimpflug device with biometry function and a reference optical biometer. International Ophthalmology, 38, 1-8(2018).

    [9] Weihong He. Development of an optical coherence tomography imaging system in ophthalmology. Optics and Precision Engineering, 16, 70-75(2008).

    [10] [10] Bradu A, Rivet S, Podoleanu A. Masterslave based optical coherence tomography f invivo, realtime, long axial imaging range of the anteri segment[C]Spie Bios, 2017, 10045: 1004518.

    [12] A Maheshwari, M A Choma, J A Izatt. Heterodyne swept-source optical coherence tomography for complete complex conjugate ambiguity removal. Journal of Biomedical Optics, 10, 1-6(2005).

    [14] [14] Fan S, Li L, Li Q, et al. Dual b dual focus optical coherence tomography f imaging the whole eye segment[J]. Biomedical Optics Express, 2015, 6(7): 2481. 2015, 6(7): 583–594.

    [15] [15] Dai Cuixia. Research on twochannel OCT imaging based on 33 fiber coupler[C]Summary of the Academic Conference of the Chinese Society of Optics, 2011. (in Chinese)

    [16] R Chen, D Wang, L Ma. Comparison of master OCT and IOL master detection in patients with cataract axial length results. Chinese Journal of Ophthalmologic Medicine, 6, 208-212(2016).

    [23] Shanshan Liu, Yi Wang, Weiqian Zhang. Large-scale axial length measuring system based on SS-OCT. Acta Photonica Sinica, 48, 0512002(2019).

    [25] Y Douini, J Riffi, A M Mahraz. An image registration algorithm based on phase correlation and the classical Lucas–Kanade technique. Signal Image & Video Processing, 11, 1-8(2017).

    [26] Hui Sun, Zhiqiang Li, Lina Sun. Sub-pixel registration of special and frequency domains for video sequences. Chinese Journal of Optics, 4, 154-160(2011).

    Tools

    Get Citation

    Copy Citation Text

    Huaiyu Cai, Weiqian Zhang, Xiaoyan Han, Yi Wang, Wenguang Chen, Xiaodong Chen. Integrated imaging system of eye axis and anterior segment based on SS-OCT[J]. Infrared and Laser Engineering, 2020, 49(4): 0413006

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Received: Dec. 11, 2019

    Accepted: --

    Published Online: May. 27, 2020

    The Author Email:

    DOI:10.3788/IRLA202049.0413006

    Topics