Acta Optica Sinica, Volume. 38, Issue 3, 315001(2018)

Simultaneous Calibration of the Intrinsic and Extrinsic Parameters of Ultra-Large-Scale Line Structured-Light Sensor

Xie Zexiao and Zhang Anqi*
Author Affiliations
  • [in Chinese]
  • show less
    Figures & Tables(16)
    Ultra-large scale line structured-light sensor 3D measurement system. (a) Real products; (b) structural representation
    Intrinsic parameters model of line structured-light
    Quasi-one-dimensional target
    Calibration process
    Solving model of a4
    Calibrating extrinsic parameters of line structured-light
    Target image of camera calibration
    Fitting error result of circulararc of multi positions
    Three standard balls
    Scanning experiment of multi positions
    Three standard balls. (a) Scatter points; (b) fitting result of single ball
    Scanning error results of standard balls. (a) Errors between the fitted and standard radius; (b) maximum error of positive and negative phase; (c) errors between standard spherical centers’ and measured distance
    Comparison of the spherical centers’ distance errors between method 1 and 2
    • Table 1. Fitting result of circulararc of multi positions

      View table

      Table 1. Fitting result of circulararc of multi positions

      No.R /mmD /mmRelative error /%Center coordinate /mm
      130.16570.15620.517807(63.6371,90.5501,1378.8962)
      230.04960.14810.492852(75.7314,-79.1138,1099.9306)
      329.89050.12590.421204(-176.8592,-107.6003,1056.3259)
      429.79130.18750.629378(31.6694,65.5633,-1124.8716)
      529.67420.16720.563452(31.0807,9.4334,-1215.8757)
      629.52960.18720.633940(113.8268,75.2721,-1110.0918)
      729.11180.15910.546514(137.1649,-86.5504,1087.2389)
      828.98640.15750.543358(-72.3052,-7.6233,1217.3944)
      928.90300.14190.490952(-53.3073,-48.7075,-1309.1590)
      1028.72480.14850.516975(256.5610,-2.2245,-1237.4199)
      1128.69630.14040.489262(-195.9803,32.6438,-1175.5815)
      1228.38400.12550.442151(-33.5220,-27.4495,1184.8420)
      1328.29640.18010.636477(-31.5336,-45.9962,1154.7424)
      1426.38390.14550.551473(174.6202,-12.2716,-1252.7506)
      1526.22100.17090.651768(-196.0525,32.5104,-1175.7969)
      Max-0.18750.651768-
    • Table 2. Multi-position fitting result of three standard balls

      View table

      Table 2. Multi-position fitting result of three standard balls

      No.Ball named1 /mmd2 /mmd3 /mmCenter distance named4 /mm
      1A30.3042-0.25920.2447AB152.2060
      B30.2496-0.22560.2591AC220.6504
      C30.1968-0.24140.2369BC221.8256
      2A30.2013-0.24930.2224AB152.2879
      B30.0540-0.23630.2196AC220.5852
      C30.1448-0.25950.2408BC221.8299
      3A30.2224-0.23780.2849AB152.2185
      B30.0755-0.24670.2738AC220.6547
      C30.1689-0.22300.2048BC221.8093
      4A30.1524-0.22370.2771AB152.2767
      B30.1429-0.26770.2562AC220.6646
      C30.1268-0.24920.2419BC221.8034
      5A30.1930-0.26110.2613AB152.2180
      B30.1529-0.20130.2229AC220.6431
      C30.1287-0.23150.2457BC221.8063
    • Table 3. Measured results of the spherical centers’ distance of step calibration

      View table

      Table 3. Measured results of the spherical centers’ distance of step calibration

      Measurement numberdAB /mmdAC /mmdBC /mm
      1152.2740220.6260221.8902
      2152.3220220.7032221.8552
      3152.2692220.7063221.7872
      4152.2431220.6708221.7816
      5152.2548220.6276221.8423
    Tools

    Get Citation

    Copy Citation Text

    Xie Zexiao, Zhang Anqi. Simultaneous Calibration of the Intrinsic and Extrinsic Parameters of Ultra-Large-Scale Line Structured-Light Sensor[J]. Acta Optica Sinica, 2018, 38(3): 315001

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Machine Vision

    Received: Sep. 27, 2017

    Accepted: --

    Published Online: Mar. 20, 2018

    The Author Email: Anqi Zhang (zhangaq-ouc@qq.com)

    DOI:10.3788/AOS201838.0315001

    Topics