Chinese Journal of Lasers, Volume. 41, Issue 10, 1016001(2014)

Optical Design of Target Range UV Telescope System

Li Bo*
Author Affiliations
  • [in Chinese]
  • show less

    Ultraviolet (UV) spectrum is an important method for photoelectric measurement. Ultraviolet target signal is weak, only a few kinds of optical materials in this spectral range can be chosen, so it′s difficult for the high-resolution ultraviolet observations. A large relative aperture and long-focus UV optical system is designed which is used in target range measurement, and it solves those problems by catadioptric imaging and reimaging. The UV optical system has the parameters of F number of 2, focal length of 400 mm, field of view (FOV) of 1°, wavelength range of 250~400 nm. The Nyquist frequency (38 lp/mm) modulation transfer function (MTF) is better than 0.7 in the telescope system FOV according to the analysis of optical software. Taking into account the environmental adaptability, focusing amount and image quality are considered at -40 ℃~60 ℃ for the UV telescope system. Result shows that the Nyquist frequency MTF is better than 0.5 after focusing which meets the design specifications and the practical application.

    Tools

    Get Citation

    Copy Citation Text

    Li Bo. Optical Design of Target Range UV Telescope System[J]. Chinese Journal of Lasers, 2014, 41(10): 1016001

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Optical Design and Fabrication

    Received: Mar. 21, 2014

    Accepted: --

    Published Online: Aug. 12, 2014

    The Author Email: Li Bo (libo0008429@163.com)

    DOI:10.3788/cjl201441.1016001

    Topics