Spectroscopy and Spectral Analysis, Volume. 30, Issue 7, 1738(2010)
LIF Spectroscopic Study of H Radical
Hydroxyl radical molecular beam was generated by DC pulsed high voltage discharge. The rotational resolution excitation fluorescence spectra of the H A 2Σ+-X 2Π (1, 0) band were observed by using second harmonious output of a nanosecond dye laser (around 282 nm). The rotational temperature of the (1, 0) band was determined to be (30±1) K based on the analysis of the intensity distribution of the H spectra. Moreover, the fluorescence decay curves of the (1, 1) band and the (0, 0) band and were obtained and the fluorescence lifetimes of A 2Σ+ (v′=1) state and the X 2Π (v″=0) state were fitted to be (637±16) and (675±13) ns, respectively.
Get Citation
Copy Citation Text
LI Jiong, DENG Lun-hua, MOU Zong-shuai, CHEN Yang-qin, YANG Xiao-hua. LIF Spectroscopic Study of H Radical[J]. Spectroscopy and Spectral Analysis, 2010, 30(7): 1738
Received: Sep. 6, 2009
Accepted: --
Published Online: Jan. 26, 2011
The Author Email: Xiao-hua YANG (xhyang@phy.ecnu.edu.cn)
CSTR:32186.14.