Chinese Journal of Lasers, Volume. 37, Issue 6, 1490(2010)

Sensitivity of Fiber Bragg Grating-Based Fabry-Pérot Interferometric Sensor

Yin Guolu1,2、*, Lou Shuqin1,2, Peng Wanjing1,2, Tao Peilin1,2, Ren Wenhua1,2, Tan Zhongwei1,2, and Liu Yan1,2
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • show less

    In the experimental research and industry applications of the fiber Bragg grating-based Fabry-Perot interfirometric (FBG FPI) sensor, its sensitivity has been widespread concerned. Considering the linewidth of the light source, the power transmission coefficient is amended and the theoretical formula of the sensitivity is deduced. Then, the key influence factors on the sensor sensitivity are discussed, including the cavity length, the coherence length of the light source, and the reflectivity of the FBG. The results show that the smaller the ratio between the cavity length and the coherence length is, the higher the sensitivity will be. When the ratio is chosen, there is an optimum reflectivity. If the reflectivity of FBG equals the optimum, the sensitivity is the highest. The results of comparison experiment on the sensitivity with different cavity lengths and sensitivity experiment on different reflectivities verify the correctness of the theoretical simulation.

    Tools

    Get Citation

    Copy Citation Text

    Yin Guolu, Lou Shuqin, Peng Wanjing, Tao Peilin, Ren Wenhua, Tan Zhongwei, Liu Yan. Sensitivity of Fiber Bragg Grating-Based Fabry-Pérot Interferometric Sensor[J]. Chinese Journal of Lasers, 2010, 37(6): 1490

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Laser physics

    Received: Mar. 22, 2010

    Accepted: --

    Published Online: Jul. 7, 2010

    The Author Email: Guolu Yin (08111030@bjtu.edu.cn)

    DOI:

    CSTR:32186.14.

    Topics