    Background

    The accurate reconstruction of γ radiation fields is fundamental to the digitalization of radiation protection and is a prerequisite for radiation dose assessment and visualization simulation. Traditional interpolation methods and uniform source activity inversion methods struggle to accurately reconstruct high-dose-rate gradient 3D radiation fields in scenarios with high-gradient, non-uniform activity distributions within large volume source terms inside nuclear facilities.

    Purpose

    This study aims to develop an inversion method for non-uniform source activity distribution and apply it to accurately reconstruct 3D gamma radiation fields of the aforementioned types.

    Methods

    Based on multi-objective source activity inversion and the Bayesian Information Criterion, an innovative inversion method for non-uniform source activity distribution was proposed. Then, the accuracy of radiation field reconstruction results in a pipeline simulation case obtained by using this method and ordinary Kriging interpolation method were compared under different source activity distribution conditions in various regions. Finally, the effectiveness of this method was further validated using measured data from inside a nuclear facility.

    Results

    Under four different activity distribution conditions in the pipeline simulation case, the proposed method achieves an ARD (average relative deviation) of less than 5% for radiation field reconstruction results in all regions, significantly outperforming the ordinary Kriging interpolation method, especially in high-dose-rate gradient areas. In the real nuclear facility scenario, the ARD between 77 reconstructed dose rate values calculated from 30 measured values and the actual measurements is only 12.69%, much lower than the result of 85.40% by ordinary Kriging interpolation.

    Conclusions

    The inversion of non-uniform source activity distribution achieved by introducing the Bayesian Information Criterion in this study is very suitable for gamma radiation field reconstruction under complex source term conditions. It provides advanced technical support for the digitalization and simulation of radiation protection based on dynamic data in nuclear facilities, enhancing its effectiveness in practical applications.

    Keywords
    Tools

    Get Citation

    Copy Citation Text

    Liye LIU, Qing FAN, Hua LI, Hui LI, Haijing JIN, Yuan ZHAO. Radiation field reconstruction method based on non-uniform source activity distribution inversion[J]. NUCLEAR TECHNIQUES, 2025, 48(4): 040502

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: NUCLEAR PHYSICS, INTERDISCIPLINARY RESEARCH

    Received: May. 22, 2024

    Accepted: --

    Published Online: Jun. 3, 2025

    The Author Email: Liye LIU (RP2024@aliyun.com)

    DOI:10.11889/j.0253-3219.2025.hjs.48.240184

    Topics