In situ measurements of atmospheric NO2 using incoherent broadband cavity-enhanced absorption spectroscopy with a blue light-emitting diode
We describe the application of incoherent broadband cavity-enhanced absorption spectroscopy (IBBCEAS) for in situ measurements of atmospheric NO2 using a blue light-emitting diode. The mirror reflectivity is determined by the transmitted intensity variation through the cavity caused by Rayleigh scattering. Concentrations of atmospheric NO2 (1 to 35 ppbv) during the seven-day period are retrieved from the absorption spectra. The IBBCEAS measurement data are compared with those of a commercial long path differential optical absorption spectroscopy. The linear regression has a correlation coefficient and a slope of 0.983 and 0.975, respectively.
Get Citation
Copy Citation Text
Liuyi Ling, Pinhua Xie, Min Qin, Wu Fang, Yu Jiang, Renzhi Hu, Nina Zheng, "In situ measurements of atmospheric NO2 using incoherent broadband cavity-enhanced absorption spectroscopy with a blue light-emitting diode," Chin. Opt. Lett. 11, 063001 (2013)
Category: Spectroscopy
Received: Nov. 29, 2012
Accepted: Feb. 25, 2012
Published Online: May. 31, 2013