Infrared and Laser Engineering, Volume. 44, Issue 11, 3270(2015)
A composite scanning method and experiment of laser radar
In traditional laser radar system, the imaging is influenced by repetition rate of selected solid-state laser as well as scanning bandwidth and scanning precision in the laser scanning system. In order to improve the scanning bandwidth and precision, DFB high-repetition-rate semiconductor laser which was amplified by EDFA was adopted as the laser source firstly. Secondly, a two-stage composite laser scanning method had been proposed with combination of PZT and galvanometer. PZT got on meticulous scanning in small areas, then galvanometer was used to deflect and finish coarse scanning on the PZT scanning field and receiving the field. The scanning accuracy had been raised and the scanning field of laser radar had been expanded simultaneously. At last, azimuth of composite scanning laser radar is ±99 mrad, pitch angle is ±49.5 mrad. Angular resolution can measure up to 0.1 mrad, and the ranging precision can reach 0.159 m.
Get Citation
Copy Citation Text
Ma Chenhao, Fu Yuegang, Gong Ping, Ouyang Mingzhao, Zhang Shuhan. A composite scanning method and experiment of laser radar[J]. Infrared and Laser Engineering, 2015, 44(11): 3270
Category: 激光技术及应用
Received: Mar. 21, 2015
Accepted: Apr. 23, 2015
Published Online: Jan. 26, 2016
The Author Email: Chenhao Ma (mch6567@163.com)
CSTR:32186.14.