NUCLEAR TECHNIQUES, Volume. 47, Issue 6, 060402(2024)

Position resolution performance of a position-sensitive 3He proportional counter based on a time-difference method

Xinyue WANG, Guorong LIU*, Jinghuai LI, Qinglei LIANG, Hao ZHOU, and Yuan TIAN
Author Affiliations
  • China Institute of Atomic Energy, Beijing 102413, China
  • show less

    Background

    Neutron localization technology can be used for monitoring spent fuel reprocessing to prevent nuclear criticality accidents.

    Purpose

    This study aims to investigate the effects of different neutron emission modes, 3He pressure, tube diameter, and moderators on the position resolution and detection efficiency of a position-sensitive 3He proportional counter.

    Methods

    Firstly, a 3He proportional counter with a tube diameter, tube length, and 3He pressure of 2.54 cm, 80 cm, and 405 300 Pa, respectively, was taken as object of study, and the Monte Carlo (MC) algorithm was employed to simulate the effects of neutrons with different energies, neutron emission modes, 3He pressures, tube diameters, and moderating bodies on the position resolution and detection efficiency of a position-sensitive 3He proportional counter. Then, the effects of the time difference of arrival (TDOA) on the location of a source in an active zone, source to tube distances, thickness of moderating body, and position resolution of the 3He proportional counter were investigated. Finally, a linear fitting analysis of the active region was performed, and the locations of inactive regions were estimated to determine the positioning ability of the 3He tube.

    Results

    Simulation results show that the position resolution of this 3He proportional counter is equal in all axial sections, and the position-resolution limit of thermal neutron source is 0.17 cm. When the thickness of the moderating body is 5 cm, and the 244Cm source is close to the external wall of the moderating body, the neutron detection efficiency is 3.0%, and the theoretical position resolution is 9.25 cm whilst experimental result of position resolution is 18.50 cm, half of the theoretical value, and the location resolution limit is 2.64 cm after processed by the linear fitting curve of the active location and a time-difference crest.

    Conclusions

    MC simulation and experimental tests show that the position-sensitive 3He proportional counter exhibits better position resolution and detection efficiency for the 244Cm source when the thickness of the moderating body is 2~3 cm, hence suitable for practical applications.

    Keywords
    Tools

    Get Citation

    Copy Citation Text

    Xinyue WANG, Guorong LIU, Jinghuai LI, Qinglei LIANG, Hao ZHOU, Yuan TIAN. Position resolution performance of a position-sensitive 3He proportional counter based on a time-difference method[J]. NUCLEAR TECHNIQUES, 2024, 47(6): 060402

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Research Articles

    Received: Mar. 18, 2024

    Accepted: --

    Published Online: Jul. 8, 2024

    The Author Email: LIU Guorong (刘国荣)

    DOI:10.11889/j.0253-3219.2024.hjs.47.060402

    Topics