Chinese Optics Letters, Volume. 11, Issue 2, 022001(2013)
Integrated ef fective emissivity computation for non-isothermal non-axisymmetric cavities
Non-axisymmetric cavities are widely used as standard blackbody sources for radiation thermometry. The integrated effective emissivity is central to the blackbody design. Integrated effective emissivities are numerically calculated for non-isothermal, non-axisymmetric cavities. The average relative deviation is 0.087% when compared with Monte-Carlo results, indicating that this method can accurately calculate the integrated effective emissivities for non-isothermal, non-axisymmetric cavities. The effects of the wavelength, temperature uniformity, and bottom inclination angle are then analyzed.
Get Citation
Copy Citation Text
Dong Liu, Yuanyuan Duan, Zhen Yang, "Integrated ef fective emissivity computation for non-isothermal non-axisymmetric cavities," Chin. Opt. Lett. 11, 022001 (2013)
Category: Optics in Computing
Received: Jun. 4, 2012
Accepted: Aug. 7, 2012
Published Online: Jan. 23, 2013
The Author Email: