Chinese Journal of Lasers, Volume. 26, Issue 4, 312(1999)

The Influence of the Inputted Refractive Index of the Small-angle Forward Scattering Laser Particle Sizer

[in Chinese], [in Chinese], and [in Chinese]
Author Affiliations
  • [in Chinese]
  • show less

    Based on the classical Mie scattering theory, the influence on the measured results which is caused by the inputted refractive index in data processing of the small-angle forward scattering laser particle sizer is investigated by means of POWELL inversion algorithm. The error would be within 0.002% in the case that the inputted refractive index equals exactly the natural one of the measured particles. Otherwise, when the inputted refractive index is in the range of (2.0,4.0) the magnitude of the error would be much less than in the range of (1.1,2.0). So, it comes to the conclusion that the value of the natural refractive index should be inputted in data processing if possible and a value larger than 2.0 should be believably chosen as the inputted refractive index if the natural refractive index of the measured particles is unknown.

    Tools

    Get Citation

    Copy Citation Text

    [in Chinese], [in Chinese], [in Chinese]. The Influence of the Inputted Refractive Index of the Small-angle Forward Scattering Laser Particle Sizer[J]. Chinese Journal of Lasers, 1999, 26(4): 312

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category:

    Received: Nov. 10, 1997

    Accepted: --

    Published Online: Aug. 9, 2006

    The Author Email:

    DOI:

    Topics