Over the last few years, fiber lasers have become the key focus in the development of new laser applications due to their significant advantages over their solid state counterparts. The key advantages of fiber lasers include their low weight and compact size, as well as relatively lower losses and ease of alignment. These characteristics make fiber lasers a crucial component of today’s optical communication, carrying terabits of information across continents.
While fiber lasers can be configured to suit multiple applications, pulsed fiber lasers in particular have recently garnered substantial attention in generating high energy pulses. These pulses serve a variety of applications, including communications, sensing, manufacturing, and medicine. Pulsing in fiber lasers can be achieved by multiple active and passive means, with the most common being -switching and mode-locking. Of the two, mode-locking is preferred for applications requiring high frequency pulses but at a lower power.
Fiber lasers can be mode locked in three ways; either actively, passively, or as a hybrid of both. Active modulation is reliable and offers tunability of various parameters, but generates a broad pulsewidth[1], and also requires bulky and expensive components. Passive modulation, on the other hand, modulates the loss and gain of the laser using saturable absorbers (SAs)[2–5] or by inducing SA action, such as nonlinear amplifying loop mirrors (NALMs)[6] and nonlinear polarization rotation (NPR)[7,8]. Pulses generated in this method have pulsewidths shorter than those generated through active means, typically in the sub-picosecond region. Another approach would be hybrid methods, which combine active and passive methods to generate self-starting mode-locked laser outputs and a shorter pulsewidth[9].
Sign up for Chinese Optics Letters TOC Get the latest issue of Advanced Photonics delivered right to you!Sign up now
Generating mode-locked pulses using the NPR technique requires two key components; namely a polarizer and an analyzer[10]. The simplicity and versatility of the NPR technique can support a large variety of applications and devices, such as the generation of supercontinuum spectra[11,12], vector solitons[13–15], all-optical flip-flop memories[16], and also in the development and fabrication of semiconductor optical amplifiers[17]. Furthermore, the NPR allows for fast saturable absorption. Recently, Smirnov et al.[18] has demonstrated an all-normal-dispersion mode-locked fiber laser using the NPR technique that can support a large variety of outputs by adjusting the settings of the polarization controller (PC). Different PC settings yield different spectrum energies, durations, shapes, and widths. Oliver et al.[19–21] demonstrated this by measuring the output polarization state, analyzing the inter-mode beat spectrum and by determining the allowed operating regimes. In this work, the relationship between pump power levels and the ellipticity of a mode-locked fiber laser of the NPR technique is successfully demonstrated. The work shows that the higher the pump power, the wider the degree of ellipticity that can accommodate a mode-locked operation.
Figure 1 shows the schematic of the experimental setup. The laser is configured in a ring cavity. A 980 nm laser diode with a maximum power of 600 mW is used as a pump source for the laser and is connected to the 980 nm port of a 980/1550 nm wavelength division multiplexer (WDM). The common output of the WDM is connected to a commercially available 65 cm long erbium-doped fiber (EDF) with a cut-off wavelength between 870–970 nm, a numerical aperture of 0.21–0.23, and an absorption coefficient of 20 dB/m at 1531 nm. The output from the EDF is now connected to a PC, along with a polarization dependent isolator (PDI) in the cavity. The PC and PDI act as the analyzer and polarizer for generating the desired mode-locked pulses using the NPR technique. Furthermore, the PDI has the additional function of eliminating potential reflection and backscattering from various sources inside the fiber cavity, thus ensuring the generation of the mode-locked pulses[7,22]. A optical coupler (OC) is placed between the PC and the PDI with the common port connected to the PC’s output, and the 90% port connected to the PDI’s input. The OC is used to extract a portion of the signal for further analysis. Finally, the output of the PDI is connected to the 1550 nm port of the WDM, thus completing the ring cavity.

Figure 1.Experimental setup of the proposed system.
The extracted signal is further divided into two equal portions using another OC. One portion of the signal is used to analyze the optical characteristics of the generated pulses, while the remaining portion is used to analyze the other characteristics of the pulses. Optical characterization is done using an optical spectrum analyzer (OSA) with a 0.02 nm resolution, while the measurement of the pulse characteristics is done using a photodetector coupled with an oscilloscope (OSC). Other equipment includes a polarimeter, a two-photon absorption (TPA) autocorrelator (AC), an optical power meter (OPM), and a radio frequency spectrum analyzer (RFSA) for signal-to-noise ratio (SNR) measurements.
To initiate, maintain, and optimize the desired mode-locked pulses, a PC consisting of half- and quarter-waveplates is used. This method allows for a shorter cavity. Additionally, the shorter design also allows for a higher repetition rate to be realized[23,24]. Under the right configuration and at a sufficiently high pump power, mode locking is observed starting at a pump power of about 37 mW. The total group velocity dispersion (GVD) of the system is estimated to be 0.12 ps/nm, with the single-mode fiber (SMF)-28 having a dispersion coefficient of 17 ps/nm/km at 1550 nm, and the EDF having a dispersion coefficient of at the same wavelength[25,26]. This indicates that the laser is operating in the soliton regime.
The relationship between the ellipticity and the pump power is taken for three conditions; , , and . Each condition corresponds to different ellipticity degrees when observed using a polarimeter, with being the ellipticity degree at which the pulse was observed at its cleanest state, while both and are the pulses obtained at the upper and lower boundaries, just before the pulses disappear when observed using the OSC. Each condition is obtained by adjusting the quarter-waveplate only, with the upper and lower boundaries being defined as the largest and smallest angle of the PC at which mode-locked pulses can be obtained. For each condition, the pump power is adjusted between 70–110 mW in increments of 10 mW. Table 1 shows the ellipticity of all three conditions, as well as their azimuth and degree of polarization (DOP), at a predetermined pump power.

Table 1. Ellipticity, DOP, and Azimuth as a Function of Pump Power
Table 1. Ellipticity, DOP, and Azimuth as a Function of Pump Power
Pump Power (mW) | Ellipticity, e(deg.) | DOP (%) | Azimuth (deg.) |
---|
70 | e1, −34.052 | 101.182 | 88.641 | e2, −30.884 | 101.515 | −76.789 | e3, −28.298 | 101.795 | −69.435 | 80 | e1, −30.624 | 101.152 | −54.777 | e2, −34.14 | 100.708 | −59.948 | e3, −17.089 | 100.916 | −41.235 | 90 | e1, −34.702 | 100.361 | −59.543 | e2, −37.979 | 100.272 | −72.697 | e3, −20.214 | 100.82 | −42.592 | 100 | e1, −36.193 | 100.396 | −57.384 | e2, −38.9 | 100.316 | −72.155 | e3, −19.622 | 100.64. | −40.7 | 110 | e1, −38.927 | 100.251 | −60.201 | e2, −41.798 | 100.446 | −89.813 | e3, −19.462 | 100.571 | −37.401 |
|
The plot of the ellipticity against the different pump power levels is given in Fig. 2. As can be seen from the figure, the increasing pump power results in the ellipticity also becoming larger for the case of and . Both show an increase in the ellipticity, from between to at a pump power of 70 mW to between to at a pump power of 110 mW. The ellipticity of on the other hand decreases initially, from about to around as the power increases from 70 to 80 mW, before stabilizing out at a value of approximately for a pump power range of between 90 to 110 mW.

Figure 2.Ellipticity, , , and at a pump power between 70–110 mW.
This behavior can be attributed to the fact that for pulse shortening to occur in a mode-locked fiber laser, the initial polarization ellipse and phase must be properly biased[8,27]. The ellipse can be resolved into right- and left-hand circular polarizations, and as the intensity of the pulse increases, due to the increasing pump power, the two components accumulate a different nonlinear phase shift relative to the intensity of the pulse. Moreover, the shift is directly related to the power difference between the two circular modes[28,29]. The result is an intensity-dependent phase shift between the coupled modes and, therefore, the nonlinear rotation of the polarization ellipse[30,31]. Feng et al.[32] demonstrated that the angle of rotation is proportional to the light intensity. In addition to this, and also depending on the angles and intensity, there is a region where a higher intensity pulse will experience higher losses. This, thus, creates an intensity equalizer. The balance between the inhomogeneous loss induced by the NPR and the mode competition effect of the EDF can create a stable multiwavelength oscillation with uniform power distribution between wavelengths. Moreover, the intensity of the pulses is also wavelength dependent. Therefore, since the initial polarization state of a mode-locked fiber laser using the NPR technique must be elliptical, the mode-locking operation over a wider degree of ellipticity is also realized.
The mode-locked pulse characteristics at a pump power of 90 mW is given in Table 2. It can be seen here that the ellipticity also influences the pulse width, thereby influencing the other parameters of the pulse as well. Figure 3 depicts an example of a pulse train measured using a fast photodiode connected to an OSC. The repetition rate of the laser is around 25 MHz, which corresponds to a cavity length of 8.2 m and a resulting cavity roundtrip time of 0.4 ns. The pulsewidth also changes, which can be seen in Fig. 4. Therefore, it can be ascertained that different ellipticity values yield different pulsewidths. Figure 5 shows the SNR of the pulse at a pump power of 90 mW. The SNR is measured to be 38 dB and is taken at the highest available resolution bandwidth of 300 Hz, using a 1 GHz bandwidth InGaAs photodetector connected to the RFSA. The inset of Fig. 5 shows the frequency spectrum up until 1 GHz.

Figure 3.Example of a mode-locked pulse from an OSC at 90 mW. The pulse train is given in the inset.

Figure 4.Pulsewidths at 90 mW pump power at different ellipticity values (a) , (b) , and (c) .

Figure 5.SNR at 90 mW. Frequency harmonics until 1 GHz (inset).

Table 2. Mode-locked Pulse Characteristics at 90 mW at a Different Ellipticity
Table 2. Mode-locked Pulse Characteristics at 90 mW at a Different Ellipticity
Ellipticity e (deg.) | Pulsewidth (ps) | FWHM (THz) | TBP | Average Output Power (mW) | Pulse Energy (nJ) | Peak Power (W) |
---|
−34.702 | 0.35 | 0.944 | 0.3304 | 0.6194 | 0.0248 | 70.79 | −37.979 | 0.34 | 1.0192 | 0.3465 | 0.6281 | 0.0251 | 73.89 | −20.214 | 0.71 | 0.0325 | 0.0231 | 0.7925 | 0.0317 | 44.65 |
|
The computed time–bandwidth product (TBP) deviates from an ideal value of 0.315 based on the transform limited sech2 pulse for a soliton regime. This indicates that the pulse is chirped, except when the ellipticity is , where the transition from SA action to saturable transmitter action occurs[32]. The presence of the small peak on the left and another smaller peak on the right could be attributed to the influence of the environment towards the laser cavity. This includes air movements and also temperature variations, which would normally be the case for NPR-based experiments.
Figure 6 shows the optical spectrum taken for ellipticity values of , , and for , , and , respectively. and show an almost identical spectrum with a number of Kelly sidebands symmetrically shown on both sides. The amplitude of the sidebands varies due to the gain of the EDF and cavity construction[33]. As for the optical spectra of , Kelly sidebands are more prominent, while on the other hand the middle part of the soliton spectrum becomes barely noticeable. The central wavelength shift, as can be seen in Fig. 6, is attributed to a Raman-induced frequency shift[34,35].

Figure 6.Optical spectrum at 90 mW for a different ellipticity.
In conclusion, the aforementioned work successfully demonstrates the relationship between pump power levels and ellipticity in mode-locked operation. The experiment uses an NPR technique to generate a mode-locked fiber laser operating at a C-band. As the pump power is increased from 70 to 110 mW, the ellipticity range that can maintain mode-locked operation is observed to also become wider.
It can also be seen that the ellipticity influences other results, such as noise, average output power, and pulsewidth. Most importantly, it is determined that for any condition, there exists at least one ellipticity value that can produce a clean pulse against any pump power.