Acta Optica Sinica, Volume. 41, Issue 22, 2223001(2021)

Impact of Position Mismatch Between Crystal and Electrode on Performance of Acousto-Optic Frequency Shifter

Xing Fan1, Wei Zhang1、*, Guanghui Guo2, Chaoqian Su1, Jing Li1, Peng Zhang1、**, and Weimin Chen1
Author Affiliations
  • 1Key Lab of Optoelectronic Technology & Systems Ministry of Education, College of Opto-Electronic Engineering, Chongqing University, Chongqing 400044, China;
  • 2AECC Sichuan Gas Turbine Establishment, Mianyang, Sichuan 621000, China
  • show less

    In order to improve the performance of the acousto-optic frequency shifter, the positional mismatch characteristics between the internal acousto-optic crystal (AOC) and piezoelectric ultrasonic transducer (PZT) electrodes are studied, and several geometric assembly mismatches between AOC and PZT electrodes are analyzed. By constructing a three-dimensional finite element model of AOC and electrode mismatch, the ultrasonic sound field in the AOC is simulated and analyzed under different axial assembly dislocation conditions. According to the acoustic field distribution characteristics of ultrasound, it can be found that the geometrical assembly dislocation will lead to the formation of an area without acousto-optic interaction inside the AOC, and the relationship between the length of this area and the amount of dislocation can be revealed. By analyzing the optical interface between the acousto-optic interaction area and the non-acousto-optic interaction area, it is found that the position mismatch will cause the double-beam interference effect in the output light, which will affect the output of the actual optical system. Based on the principle of double-beam interference, an experimental system is built to measure the length of without acoustic interaction occurs region, and the results prove the rationality of the theoretical analysis.

    Tools

    Get Citation

    Copy Citation Text

    Xing Fan, Wei Zhang, Guanghui Guo, Chaoqian Su, Jing Li, Peng Zhang, Weimin Chen. Impact of Position Mismatch Between Crystal and Electrode on Performance of Acousto-Optic Frequency Shifter[J]. Acta Optica Sinica, 2021, 41(22): 2223001

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Optical Devices

    Received: Jan. 22, 2021

    Accepted: Jun. 3, 2021

    Published Online: Oct. 29, 2021

    The Author Email: Zhang Wei (zhangwei1213052@126.com), Zhang Peng (zhangpeng@cqu.edu.cn)

    DOI:10.3788/AOS202141.2223001

    Topics