Chinese Optics, Volume. 16, Issue 4, 833(2023)
Cophasing error of the Golay3 sparse aperture imaging system
Multiple sub-aperture interference imaging enables the images formed by the sparse aperture imaging system to have a higher resolution after the cophasing error is corrected. In this paper, the MTF and surface target imaging of the system are analyzed with a Golay3 sparse aperture imaging system as the research object when there are different piston and tilt errors among the sub-apertures. A Golay3 sparse aperture imaging system was developed to carry out an imaging experiment with the USAF1951 resolving power test target as the area target. Three-aperture synthetic imaging is achieved by adjusting the position of the plane mirror in the light beam deflection and the adjustment module to correct the piston and tilt errors of the sub-apertures. The results of a theoretical analysis are then verified. According to calculations, the developed system’s angular resolution of 1.38 μrad is close to the equivalent single-aperture imaging system’s theoretical resolution of 1.18 μrad. The developed Golay3 sparse aperture imaging system can correct the cophasing errors and improve the imaging resolution.
Get Citation
Copy Citation Text
Jun-hong QIAN, Rong-zhu ZHANG. Cophasing error of the Golay3 sparse aperture imaging system[J]. Chinese Optics, 2023, 16(4): 833
Category: Original Article
Received: Sep. 26, 2022
Accepted: --
Published Online: Jul. 27, 2023
The Author Email: