Optoelectronic Technology, Volume. 41, Issue 3, 223(2021)

Research on Air Electrostatic Discharge Problem Based on Rugged Display

Li ZHAO, Guangteng WANG, and Jianjun CHEN
Author Affiliations
  • The 55th Research Institute of China Electronics Technology Group Corporation, Nanjing 210016, CHN
  • show less

    A bright line appeared on the display screen of a rugged display in air Electrostatic Discharge (ESD) 15 kV test. For the problem, an effective rectification method was proposed,which was to deal with the lap joint between the coated shielding glass and the shell of rugged display. It was included that:(1)The ITO film layer should be bare or have silver paste edge for the edge lap joint mode of the coated shielding glass, (2) The thickness of the conductive pads at the gap between the coated shielding glass and the shell of rugged display should increase in the case that the display effect could not be affected. The experiment results showed that: this method could make the rugged display pass the air ESD 15 kV test easily. It could also provide technical support for air electrostatic discharge design of subsequent rugged displays,showing important practical significance.

    Tools

    Get Citation

    Copy Citation Text

    Li ZHAO, Guangteng WANG, Jianjun CHEN. Research on Air Electrostatic Discharge Problem Based on Rugged Display[J]. Optoelectronic Technology, 2021, 41(3): 223

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Research and Trial-manufacture

    Received: Apr. 15, 2021

    Accepted: --

    Published Online: Oct. 26, 2021

    The Author Email:

    DOI:10.19453/j.cnki.1005-488x.2021.03.012