Journal of Radiation Research and Radiation Processing, Volume. 42, Issue 2, 020302(2024)

Monte Carlo simulation of errors in gantry angle and multi-leaf collimators on intensity modulated arc therapy radiation dose

Ruohui ZHANG1, Yulan GAO2, Wenwen BAI1、**, Huipeng MENG3, Keqiang WANG4, and Zifeng CHI1、*
Author Affiliations
  • 1Department of Radiation Oncology, The Fourth Hospital of Hebei Medical University, Shijiazhuang 050011, China
  • 2Department of Endoscopy, Hebei General Hospital, Shijiazhuang 050051, China
  • 3Radiotherapy Center, Tianjin First Central Hospital, Tianjin 300384, China
  • 4Biomedical Engineering Department, Tianjin University, Tianjin 300072, China
  • show less

    This study aimed to investigate the impact of conventional linear accelerator errors in the gantry angle and multi-leaf collimators (MLCs) on the intensity-modulated arc therapy (IMAT) radiation dose for brain tumors. Seven typical planning datasets of patients with brain tumors were randomly selected and retreated using the IMAT conventional linear accelerator Varian 23EX. Random and system errors were introduced to modify these plans while maintaining the remaining treatment information. The dose-volume parameters of the target and critical organs were compared and analyzed. The results showed that for random single-sided MLCs errors, if a group of errors was moved outward by 2 mm, the planning target volume (PTV)-Dmean increased by approximately 2.7%. If one side of the MLCs expanded outward with MLC-1, MLC-2, and MLC-rnd, the mean deviations of PTV-Dmean were 1.12%, 2.15%, and 1.15%, respectively, and the Dmean deviations of the lenses were 5.25%, 9.97%, and 5.49%, respectively. The maximum deviation of PTV-Dmean because of the deviation of two sets of leaves caused by system errors (±2 mm) was 0.8%, and maximum dose and Dmean of the lens and brainstem increased by 11.4%, 15.8% and 1.99%, 1.07%, respectively. By introducing a gantry angle error, the maximum doses of PTV-Dmin and-Dmean reduced by 2.75% and 0.35%, respectively. An incorrect gantry position results in significant changes in the dosimetric deviation of the OAR dose-volume histogram, especially for the lens. Note that the maximum and mean dose deviations of a patient’s lens if the gantry deviation (–2°) were 16.9% and 38.5% higher than those of the reference plan, respectively. The dose deviation caused by random errors of the MLCs leaves was influenced by the actual size of the random displacement errors of the leaves and weight of the beam subfield at a specific arc segment. The maximum dose deviation occurs if MLCs move to the maximum simulation error (±2 mm). The gantry rotation error had no significant impact on the target area PTV dose distribution; however, it had a significant dose deviation for the OAR.

    Keywords
    Tools

    Get Citation

    Copy Citation Text

    Ruohui ZHANG, Yulan GAO, Wenwen BAI, Huipeng MENG, Keqiang WANG, Zifeng CHI. Monte Carlo simulation of errors in gantry angle and multi-leaf collimators on intensity modulated arc therapy radiation dose[J]. Journal of Radiation Research and Radiation Processing, 2024, 42(2): 020302

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Research Articles

    Received: Nov. 15, 2023

    Accepted: Jan. 16, 2024

    Published Online: May. 28, 2024

    The Author Email: Wenwen BAI (白文文), Zifeng CHI (迟子锋)

    DOI:10.11889/j.1000-3436.2023-0068

    Topics