Chinese Journal of Lasers, Volume. 45, Issue 12, 1204001(2018)

Collinear Autocorrelation Measurement of Ultrashort Laser Pulse Based on Michelson Interferometer

Wei He1、*, Minghuan Cui1, Didi Song1, Chaochao Qin1, and Yuhai Jiang2
Author Affiliations
  • 1 College of Physics and Material Science, Henan Normal University, Xinxiang, Henan 453000, China
  • 2 Shanghai Advanced Research Institute, Chinese Academy of Sciences, Shanghai 201210, China
  • show less

    The collinear autocorrelation measurement method is adopted based on the principle of Michelson interferometer, in which the intensity autocorrelation and the two-dimensional electric field autocorrelation are simultaneously measured. A Gaussian function is used to fit the intensity autocorrelation data and the full width at half maximum of the measured laser pulse in time domain is about 96.2 fs. From the interference fringe distribution of two-dimensional electric field autocorrelation obtained by the CMOS imaging sensor, the tilt information of pulsed light spot wavefront phase can be obtained. Moreover, the Fourier series analysis tool is adopted to fit the interference fringes shifting with time delay. Within the restriction of delay stage accuracy, a weak component at 1090 nm is disclosed in the pulsed laser power spectrum.

    Tools

    Get Citation

    Copy Citation Text

    Wei He, Minghuan Cui, Didi Song, Chaochao Qin, Yuhai Jiang. Collinear Autocorrelation Measurement of Ultrashort Laser Pulse Based on Michelson Interferometer[J]. Chinese Journal of Lasers, 2018, 45(12): 1204001

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: measurement and metrology

    Received: Jun. 8, 2018

    Accepted: Jul. 30, 2018

    Published Online: May. 9, 2019

    The Author Email:

    DOI:10.3788/CJL201845.1204001

    Topics