Opto-Electronic Engineering, Volume. 43, Issue 8, 18(2016)

Fabrication and Optimization of Enzyme Biosensors Based on Hollow Fiber with Dielectric Film

HE Yujing*, CHEN Pan, ZHU Xiaosong, TANG Xiaoli, and SHI Yiwei
Author Affiliations
  • [in Chinese]
  • show less

    A chemiluminescence sensor is proposed based on the dielectric coated silver hollow fiber. A ray optics model is established for the multi-layer hollow fiber to analyze the loss spectrum and chemiluminescent characteristics. And parameters such as film surface roughness and thickness are taken into consideration. The fabrication techniques for coating sol-gel sensing film inside the hollow fiber are developed. A sensing system is designed and established for detecting hydrogen peroxide concentration and a high sensitivity (22.8 nW/(mmol·L-1)) and good detection limit (3μmol/L) are achieved. This sensor has a good performance in 200 hours. It has potential applications in environmental monitoring and biological analysis fields for its simple operation, fast response, and miniaturization.

    Tools

    Get Citation

    Copy Citation Text

    HE Yujing, CHEN Pan, ZHU Xiaosong, TANG Xiaoli, SHI Yiwei. Fabrication and Optimization of Enzyme Biosensors Based on Hollow Fiber with Dielectric Film[J]. Opto-Electronic Engineering, 2016, 43(8): 18

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category:

    Received: Jul. 17, 2015

    Accepted: --

    Published Online: Sep. 12, 2016

    The Author Email: Yujing HE (11110720014@fudan.edu.cn)

    DOI:10.3969/j.issn.1003-501x.2016.08.004

    Topics