Chinese Journal of Lasers, Volume. 33, Issue 6, 819(2006)

Micro-Calorimetry Based on Time-Resolved Interferometer

[in Chinese]*
Author Affiliations
  • [in Chinese]
  • show less

    A micro calorimetry based on interferometer to measure the light-induced reaction volume and quantity of heat is studied. The principle to get the reaction volume and quantity of heat is introduced. The method is used to investigate the reaction of myoglobin (Mb) with CO after light excitation. Accompanying the reaction of Mb with CO, the quantity of heat and reaction volume are changed which could lead to the variation of the index of refraction of Mb. The thermodynamic information could be obtained through measuring the phase variation. The experiment to get the reaction volume and quantity of heat for the reaction of Mb with CO is done at 273 K to 301 K with a time window of 10-6 s to 10-1 s. The measured reaction enthalpy is 80 kJ/mol, the reaction volume is 10 mL/mol.

    Tools

    Get Citation

    Copy Citation Text

    [in Chinese]. Micro-Calorimetry Based on Time-Resolved Interferometer[J]. Chinese Journal of Lasers, 2006, 33(6): 819

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: measurement and metrology

    Received: Oct. 27, 2005

    Accepted: --

    Published Online: Jun. 13, 2006

    The Author Email: (xpcai@hit.edu.cn)

    DOI:

    Topics