Chinese Optics Letters, Volume. 10, Issue s2, S23101(2012)
Temperature coef f icient of resistance of reduced graphene oxide
The influence of technique parameters on the temperature coefficient of resistance (TCR) of reduced graphene oxide (RGO) films is studied. These technique parameters include the ultrasonic time, solution concentration, and heat treatment temperature. Results show that, the best technique parameters are ultrasonic time of 14 h, solution of 0.12 ml, and annealing temperature of 800 oC, and on this point, TCR value of RGO is from -0.67% to -1.36% at the different film thicknesses.
Get Citation
Copy Citation Text
Jinqiu Liu, Changlong Cai, Haifeng Liang, "Temperature coef f icient of resistance of reduced graphene oxide," Chin. Opt. Lett. 10, S23101 (2012)
Category: Thin films
Received: May. 25, 2012
Accepted: Jun. 9, 2012
Published Online: Dec. 6, 2012
The Author Email: