High Power Laser and Particle Beams, Volume. 36, Issue 11, 115002(2024)

Operational characteristics of and influencing factors on the triggered vacuum switch for electromagnetic pulse welding

Chengxiang Li1, Dan Chen1, Jian Du1,2, Zhigang Liao1,2, and Yan Zhou1、*
Author Affiliations
  • 1State Key Laboratory of Power Transmission Equipment Technology, School of Electrical Engineering, Chongqing University, Chongqing 400044, China
  • 2Yongchuan Power Supply Branch of State Grid Chongqing Electric Power Company, Chongqing 402160, China
  • show less

    Electromagnetic pulse welding (EMPW) is a key application of pulsed power technology in materials processing, where triggered vacuum switch (TVS) is frequently employed as discharge switch. Based on the specific behavior of the EMPW process, this paper presents a detailed investigation into the operational characteristics of a new domestically produced TVS, named ZKTC. The study focuses on the switch's behavior during the triggering, conducting, and initial discharging stages. The effects of circuit parameters on ZKTC’s operation were analyzed through simulations. A trigger device combining a Marx circuit and a pulse transformer was developed, featuring adjustable pulse widths (0–10 μs) and adjustable voltage amplitudes (0–20 kV). Based on ZKTC, a high-current pulsed generator testing platform with a discharge energy of 27 kJ was constructed to perform experimental analyses. The results indicate that the voltage amplitude and rising edge of the trigger signal significantly influence the ZKTC triggering process. While the working voltage amplitude of the main discharge circuit impacting the directional migration rate of charged particles and the discharge current during the conducting stage, modifying the parameters of the switch discharge circuit and accelerating the voltage drop rate. This, in turn, has a significant effect on both the conducting and discharging stages.

    Keywords
    Tools

    Get Citation

    Copy Citation Text

    Chengxiang Li, Dan Chen, Jian Du, Zhigang Liao, Yan Zhou. Operational characteristics of and influencing factors on the triggered vacuum switch for electromagnetic pulse welding[J]. High Power Laser and Particle Beams, 2024, 36(11): 115002

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category:

    Received: Sep. 27, 2024

    Accepted: Oct. 18, 2024

    Published Online: Jan. 8, 2025

    The Author Email: Yan Zhou (zhouyan1992@cqu.edu.cn)

    DOI:10.11884/HPLPB202436.240345

    Topics