Chinese Journal of Lasers, Volume. 37, Issue S1, 94(2010)
Study on Saturation Area of Detector Based on Envelope of Airy Function
Detectors will be saturated when exposed to intense light. There is certain dependence among saturated area, light intensity and saturation threshold. The energy distribution of far-field spot is described with Airy function, due to the constraint of pupil. Saturated area formula has been obtained by the study of the envelope of Airy function. Exposed to a beam of intense light, the saturated area is proportional to the 2/3-th power of light intensity and inversely proportional to the 2/3-th power of saturation threshold. The formula is verified by irradiation experiment. The result has certain significance in saturation estimation and laser blinding.
Get Citation
Copy Citation Text
Han Kai, Xu Xiaojun. Study on Saturation Area of Detector Based on Envelope of Airy Function[J]. Chinese Journal of Lasers, 2010, 37(S1): 94
Category:
Received: Mar. 16, 2010
Accepted: --
Published Online: Oct. 29, 2010
The Author Email: Kai Han (hankai0071@126.com)