Chinese Journal of Lasers, Volume. 37, Issue S1, 94(2010)

Study on Saturation Area of Detector Based on Envelope of Airy Function

Han Kai* and Xu Xiaojun
Author Affiliations
  • [in Chinese]
  • show less

    Detectors will be saturated when exposed to intense light. There is certain dependence among saturated area, light intensity and saturation threshold. The energy distribution of far-field spot is described with Airy function, due to the constraint of pupil. Saturated area formula has been obtained by the study of the envelope of Airy function. Exposed to a beam of intense light, the saturated area is proportional to the 2/3-th power of light intensity and inversely proportional to the 2/3-th power of saturation threshold. The formula is verified by irradiation experiment. The result has certain significance in saturation estimation and laser blinding.

    Tools

    Get Citation

    Copy Citation Text

    Han Kai, Xu Xiaojun. Study on Saturation Area of Detector Based on Envelope of Airy Function[J]. Chinese Journal of Lasers, 2010, 37(S1): 94

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category:

    Received: Mar. 16, 2010

    Accepted: --

    Published Online: Oct. 29, 2010

    The Author Email: Kai Han (hankai0071@126.com)

    DOI:10.3788/cjl201037s1.0094

    Topics