Opto-Electronic Engineering, Volume. 43, Issue 11, 13(2016)

Improved Illumination for Steel Ball Surface Inspection System

SONG Yuhang*, WANG Zhong, FU Luhua, JIANG Meihua, and ZHANG Kai
Author Affiliations
  • [in Chinese]
  • show less

    An improved illumination is developed to reduce the false acceptance rate of the existing steel ball surface inspection system. A mathematical model was established to help finding out the factors having influence on the illumination uniformity. And Lighttools simulation was applied to simulate the influence of the light source shielding screen shape and guide rail transmittance on illumination uniformity. In our experiment, a new illumination device based on the analysis of simulation performance was designed and implemented into the inspection system. The result shows that the improved illumination reduces the false acceptance rate to 0.02% and increases the inspection accuracy. The improved illumination meets the theoretical derivation and expectation of computer simulation.

    Tools

    Get Citation

    Copy Citation Text

    SONG Yuhang, WANG Zhong, FU Luhua, JIANG Meihua, ZHANG Kai. Improved Illumination for Steel Ball Surface Inspection System[J]. Opto-Electronic Engineering, 2016, 43(11): 13

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category:

    Received: Apr. 8, 2016

    Accepted: --

    Published Online: Dec. 9, 2016

    The Author Email: Yuhang SONG (songyuhang@tju.edu.cn)

    DOI:10.3969/j.issn.1003-501x.2016.11.003