1MOE Key Laboratory of Advanced Micro-Structured Materials, School of Physics Science and Engineering, Tongji University, Shanghai 200092, China
2State Key Laboratory of Surface Physics, Key Laboratory of Micro- and Nano-Photonic Structures (Ministry of Education) and Department of Physics, Fudan University, Shanghai 200433, China
3School of Optoelectronic Engineering, Guangdong Polytechnic Normal University, Guangzhou 510665, China
Bound states in the continuum (BICs) in artificial photonic structures have received considerable attention since they offer unique methods for the extreme field localization and enhancement of light-matter interactions. Usually, the symmetry-protected BICs are located at high symmetric points, while the positions of accidental BICs achieved by tuning the parameters will appear at some points in momentum space. Up to now, to accurately design the position of the accidental BIC in momentum space is still a challenge. Here, we theoretically and experimentally demonstrate an accurately designed accidental BIC in a two-coupled-oscillator system consisting of bilayer gratings, where the optical response of each grating can be described by a single resonator model. By changing the interlayer distance between the gratings to tune the propagation phase shift related to wave vectors, the position of the accidental BIC can be arbitrarily controlled in momentum space. Moreover, we present a general method and rigorous numerical analyses for extracting the polarization vector fields to observe the topological properties of BICs from the polarization-resolved transmission spectra. Finally, an application of the highly efficient second harmonic generation assisted by quasi-BIC is demonstrated. Our work provides a straightforward strategy for manipulating BICs and studying their topological properties in momentum space.
【AIGC One Sentence Reading】:We demonstrate accurate design and control of accidental bound states in the continuum in momentum space, enabling manipulation of light-matter interactions and efficient second harmonic generation.
【AIGC Short Abstract】:We demonstrate the accurate design of accidental bound states in the continuum (BICs) in momentum space using a two-coupled-oscillator system. By adjusting the interlayer distance between gratings, we control the BIC position. We also introduce a method to observe BIC topological properties from polarization-resolved transmission spectra. As an application, we showcase efficient second harmonic generation assisted by quasi-BIC. Our work offers a strategy to manipulate and study BICs in momentum space.
Note: This section is automatically generated by AI . The website and platform operators shall not be liable for any commercial or legal consequences arising from your use of AI generated content on this website. Please be aware of this.
1. INTRODUCTION
Bound states in the continuum (BICs) are an exception to conventional bound states. They lie inside the continuum and coexist with extended states, but they remain perfectly localized without any radiation [1]. Although BICs were first proposed by von Neumann and Wingner in quantum mechanisms [2], they are general solutions of wave equations and have since been identified in various systems [3–7]. By introducing external perturbations or adjusting parameters of the system, a true BIC will collapse to sharp Fano resonance with ultrahigh quality () factor that is called quasi-BIC [8–11], which can boost light-matter interactions for practical applications in a variety of lasing [12–14], biosensors [15–17], unidirectional transfer [18,19], nonlinear devices [20–22], and enhancement of optical chirality [23–28].
As singular points of polarization in momentum space, the topological properties of BICs ensure that they can be continuously shifted in momentum space [29]. By merging multiple BICs at different places of momentum space, the problem of scattering losses induced by fabrication imperfections can be effectively overcome [22,29,30]. Besides, by breaking the symmetry of the system or adjusting the structural parameters, various evolution phenomena including the generation and annihilation of BICs have been observed [29–33]. Different BICs can be categorized with respect to the physical origin of far-field radiation suppression. When a system possesses a reflection or rotational symmetry, the modes with different symmetry classes are completely decoupled. A bound state of one symmetry class can be embedded in the continuous spectrum of another symmetry class, where their coupling is forbidden as long as the symmetry is preserved. This kind of BIC is called symmetry-protected BIC [1,10], which appears in a variety of photonic structures such as metasurfaces [10,11,25,34–37], photonic crystal slabs [38–41], gratings [18,42–44], photonic wave-guides [45,46], and so on. Compared with the symmetry-protected BIC, the accidental BIC obtained by tuning the parameters of the system stems from the complete suppression of the radiation of the bound state into the continuous channels [8,46]. In many cases, some accidental BICs are known as Friedrich-Wintgen (FW) BIC [8], which can be interpreted as destructive interference in two radiating channels from two coupled resonators of a system [47–50]. When the two resonators in the system are separated in some distance, the accidental BIC becomes a Fabry–Perot (FP) BIC [1,6,47]. Interestingly, the formation condition of FP BICs is just the standing wave condition when the accumulated propagation phase shift of the wave after the round-trip is the integer multiple of . In general, the symmetry-protected BICs are fixed at highly symmetric points in momentum space [10,11,34], while the position of accidental BICs strongly depends on the geometric parameters [1,22,30,32]. Up to now, to accurately design the position of the accidental BIC in momentum space by demand remains an open question.
In this paper, we propose bilayer gratings as a coupled-oscillators system to realize an accurately designed F-P BIC in momentum space. We show that the position of the F-P BIC can be freely designed in momentum space by changing the interlayer distance between the gratings to tune the propagation phase shift related to wave vectors. We further study the evolution of BICs in momentum space. Particularly, we propose a general approach for extracting the polarization vector fields to observe the topological properties of BICs from the transmission spectra. Finally, as an example of application, the highly efficient second harmonic generation assisted by quasi-BIC is demonstrated. Our work offers a route to accurately design accidental BICs, which is very useful in the applications of BICs.
Sign up for Photonics Research TOC Get the latest issue of Advanced Photonics delivered right to you!Sign up now
2. PRINCIPLE AND DESIGN
The FP BIC is a type of accidental BIC obtained through parameter tuning, which is commonly found in systems with two resonances coupled to the same radiation channel. Figure 1 shows the typical theoretical model. We consider two resonance amplitudes evolving in time as . According to temporal coupled-mode theory, the Hamiltonian can be written as follows [1]: where and are the near-field coupling and far-field coupling, respectively. Here is the propagation phase shift between two resonances. Herein, the resonance frequencies of two resonators are identical. The two eigenvalues of are and the real and the imaginary parts of two eigenmodes are We can further obtain the formation condition of the BIC, where represents the wave vector of the single resonator in the direction of propagation, is the incident angle, and and denote the refractive index of the background and distance between two resonances, respectively. When , i.e., satisfying the BIC condition, one of the two eigenmodes becomes a BIC with a purely real eigenfrequency, and the other eigenmode becomes more lossy with twice the original decay rate. Notice that the propagation phase shift related to vectors can be flexibly tuned by changing the interlayer distance between two resonators. As a result, the formation condition of the BIC can be maintained for different wave vectors. In other words, the position of the BIC can be arbitrarily designed in momentum space.
Figure 1.Theoretical model of the two-coupled-oscillator system.
For a real structure, the optical features of resonant guided modes in grating can be described by using coupled-mode theory. Around the resonance frequency, the electromagnetic response of the grating can be considered as a single resonator model (SRM) [51]. Herein, we consider a two-coupled-resonator model consisting of two identical one-dimensional dielectric gratings as a common platform to demonstrate that such a BIC can be freely designed in momentum space. Figure 2(a) shows the schematic of the proposed structure in which the width and height of infinitely long bars with gaps are and , respectively, where is the lattice constant. The interlayer distance between the gratings is denoted by , and the dielectric constant is . In general, the resonant responses of the grating exhibit an asymmetrical Fano line shape. To better consider the grating as a resonator, we select the proper material with low refractive indices contrast compared to the background. Herein, we first calculate the dispersion relation of the single grating for the transverse magnetic (TM) polarization, as shown in Fig. 2(b). It can be seen that the resonance frequency will decrease as the incident angle increases. Besides, the optical response of single grating can be described by the SRM around the angular frequency of the guided mode resonances (GMRs). According to the SRM, the reflectance can be expressed as [51], where and . By fitting the reflectance spectrum of single grating by the SRM at , one can see that the optical features of single grating around the resonance frequency match well with the SRM (see Appendix A). Thus, the optical response of single grating can be described by a single resonator model. Next, a freely designed BIC will be revealed in two-coupled-oscillator system consisting of bilayer gratings.
Figure 2.(a) Schematic of the bilayer grating for a freely designed BIC. (b) Dispersion relation of single layer grating. (c) Band structure of the bilayer grating at . The red circle represents the position of . (d) The corresponding factors. (e) Far-field polarization states around BIC. (f) The dependence of BICs on the interlayer distance and . The inset gives factors around the four BIC modes () for four different interlayer distances indicated by the color points.
Now, we demonstrate that the BIC supported by bilayer gratings can be designed by adjusting the interlayer distance between two gratings. Based on the formation condition of BIC, one can expect the emergence of BIC by designing suitable interlayer distance at arbitrary wave vectors. For instance, when (i.e., ) and , the interlayer distance can be obtained from Eq. (4). The calculated band structures of bilayer gratings at is shown in Fig. 2(c), where the bands above and below correspond to and bands, respectively. In this case, becomes a BIC with a purely real eigenfrequency at . Notice that there is another band marked by the gray solid line, which stems from Brillouin zone folding. Figure 2(d) shows the factors distribution of two modes along the direction, in which a BIC with infinite factor is formed by the destructive interference between two resonators. Herein, the blue and black lines correspond to the factors of and bands, respectively. Furthermore, as polarization singularities, the topological properties of BICs can be revealed by calculating the far-field polarization states. For more clearness, the far-field polarization states around the BIC in momentum space are shown in Fig. 2(e). It can be seen that the far-field polarization state is undefined at BIC point, which is a polarization singularity in momentum space. Moreover, the position of the BIC can be arbitrarily controlled for different wave vectors by adjusting the interlayer distance. Based on the formation condition of BIC, the dependence of BICs on the interlayer distance and is given by the blue line in Fig. 2(f). Further, we select four points in the blue line and calculate the corresponding factors around the four BIC modes , as shown in the inset of Fig. 2(f). When the interlayer distance is , the position of BIC can be expected to appear at [corresponding to the red point in Fig. 2(f)]. In general, the BICs will disappear, and the positions of accidental BICs are undefined when the geometric parameters change. However, by decreasing (increasing) the interlayer distance, the increase (decrease) in propagation phase shift related to the wave vector can be compensated. As a consequence, the position of the BIC can be arbitrarily designed in momentum space.
Based on the formation condition and the conservation of topological charge, we can predict and understand the behaviors of BICs when the parameters of the system are varied. To intuitively show the evolution of BICs that are robust in momentum space, we show the far-field polarization maps of the band at relatively small momentum space in Fig. 3. Our system exhibits {, , } symmetries, and the typical band structure for is shown in Fig. 3(a). Owing to the non-zero tangential momentum of the wave vector, the dual BICs marked by the red circle will exist at at the symmetric positions in momentum space, as shown in Fig. 3(a). Figure 3(b) gives the polarization vectors together with the factor as the background of the band in momentum space for , where the white arrows represent the distribution of polarization fields. There are two BICs carrying the same topological charges on the axis, and the topological charge can be defined by [29] where indicates a closed path in reciprocal space that surrounds the BIC along the counterclockwise direction. Here, is the angle of the polarization vector, and . In addition, the sign of the component of polarization vectors near the BIC and the polarization vectors winds around the BICs with charge are shown in Fig. 3(c). By decreasing , the dual BICs with the same charges gradually merge to the center in momentum space, as shown in Fig. 3(d). Owing to the conservation of topological charges: annihilation cannot happen between two BICs with the same charge. It is noted that such accidental BICs are a common wave phenomenon in optical systems, and merging evolution of accidental BICs also exists in other structures [22,29,32,52–54]. Usually, the FW-type accidental BICs come from the coupling between the guided mode resonances and Fabry–Perot modes [32]. Different from the previous works, the formation of a Fabry–Perot type accidental BIC stems from the coupling between two oscillators, and its position is controllable.
Figure 3.(a) Simulated band structure at . (b) Calculated polarization vectors around BICs with the factors as background in the Brillouin zone for . (c) Sign of polarization vector components around BICs. (d) Calculated polarization vectors around BICs with the factors as background in the Brillouin zone for .
The characteristics of BICs can be observed by measuring the transmission spectra of the structure. To meet the requirement of low refractive index contrast compared to air, the Teflon is used as the dielectric material for grating fabrication in the microwave region. According to the manufacturer datasheet, the relative permittivity of Teflon is and the loss tangent is tan at 30 GHz. It should be pointed out that the material loss would hardly affect the position of BIC, but it would affect the factor of quasi-BIC. The larger the material loss is, the more the decrease of the factor would be. In principle, the size of the structure and operating wavelength can be arbitrarily designed based on the scaling law. In the near-infrared or visible region, can be used as a candidate material. Owing to the limitation of experimental conditions, as an example, we perform the experiment in the microwave region. We design two samples to observe the properties of BICs. In the two fabricated samples, each grating has the same lattice constant and gap width , whereas the interlayer distance between the upper and bottom gratings is selected to be 7.35 mm and 9.1 mm, respectively. The sizes of two samples are both , and the size of the unit cell is smaller than the wavelength. It should be pointed out that the sample size under test is related to the waist of the input beam as it must be shorter than the sample size in order to avoid any undesired diffraction at the edge of the sample. In general, the side length of the sample should be greater than 50 times the incident wavelength. Herein, the side length of the sample is 49 cm, which is 51 times the incident wavelength. In the experiment, the sample is mounted to a holder and fixed on a rotating platform in the middle of two lens antennas. One of the antennas acts as transmitter, and the other works as receiver. Both antennas are connected to a vector network analyzer (VNA, Keysight N5245B) via coaxial cables, and the experimental measurements are performed in an anechoic chamber. The schematic view and photos of the experimental setup and sample are shown in Fig. 4. In fact, the lens antenna can transmit a Gaussian-like beam with a larger waist radius, which has a smaller divergence angle and better angular resolution. Thus, we use a lens antenna rather than a horn antenna as the transmitting and receiving antennas. Of course, the presence of lenses will bring some ripples with noticeable amplitude in the measured -parameters because of the multiple reflections between the lenses and the sample under test. To overcome this problem, time-domain gating is applied. The transmission coefficient of the sample can be obtained by measuring the receiving signal () with and without the sample.
Figure 4.Schematic view and photos of the experimental setup and sample.
To determine the position of BIC, we first give the simulated transmittance spectra of the structure along the direction of at , as shown in Fig. 5(a). One can see that the BIC is located in the vicinity of , and the simulated transmittance spectra agree well with the band structure in Fig. 2(c). In addition, the far-field polarization of the eigenmode is undefined at BIC point, i.e., [55], where represent the Stokes parameters. We can use the polarization-resolved transmission spectra with magnitude and phase at two polarizer angles, i.e., along and , to extract the polarization vector fields at the frequency interested. The corresponding Stokes parameters can be written as Here, is the coefficient of transmission converted into the polarization for the -polarized incident light, and similarly for the other elements. and can be extracted from transmission spectra with magnitude and phase, and for the direct transmission process is obtained by fitting the background in the transmission spectra to the transmission coefficients through a uniform slab with the same thickness and with an effective dielectric constant [56]. The detailed derivation of the above expressions is given in Appendix B. To more accurately determine the position of the BIC, Fig. 5(b) shows the Stokes parameters at . It is seen that all components of Stokes parameters are equal to zero at . As a result, the position of BIC can be accurately determined, which is consistent with that in Fig. 2(c). In order to further confirm the theoretical results, we experimentally observe the transmittance spectra of the structure at , as shown in Fig. 5(c). Overall, the measured results agree with the simulated results. Owing to the influence of intrinsic loss and scattering loss induced by fabrication imperfection, the linewidth of the measured transmission spectra is somewhat widened. Furthermore, we set the interlayer distance to observe the properties of BICs. For this structure, the position of the BIC is expected to appear at , corresponding to the case at the incident angle of 15°. In Fig. 5(d), we show the simulated transmittance spectra of the structure. We see that a BIC occurs in the vicinity of , and the corresponding measured transmittance spectra are shown in Fig. 5(f). As predicted, when the interlayer distance increases, the position of BIC moves along the axis [in accordance with Fig. 2(f)]. Similarly, all components of Stokes parameters for the second structure are equal to zero for BIC point at , as shown in Fig. 5(e). These findings experimentally demonstrate that the F-P BICs can be accurately designed and observed by demand.
Figure 5.Simulated transmittance spectra of the structure for TM polarization at (a) and (d) . The circles represent the positions of BICs. (b), (e) Corresponding Stokes parameters around BICs points. (c), (f) Corresponding experimental results.
To further demonstrate the topological features of BIC in momentum space, we calculate the far-field polarization states around BIC under different interlayer distances. Here the polarization vectors are calculated from the eigenfields in the unit cell using COMSOL Multiphysics, and the Stokes parameters are , , , and , respectively. Figure 6(a) shows the calculated polarization vectors in momentum space when , where a polarization singularity with charge (i.e., BIC) at appears. As increases from 0.99 to 1.23, the polarization singularity moves along the axis. In the case of , the polarization singularity is located at , as shown in Fig. 6(c). Utilizing the method of extracting eigenfields, we can theoretically understand the topological characteristics of the BIC in momentum space. Nevertheless, extracting the eigenfields experimentally is quite difficult, particularly in the optical region. As a result, to experimentally observe the topological features of the BIC in momentum space remains a challenge. To reduce the difficulty of the experiment, we propose a general method and rigorous numerical analyses for extracting the polarization vector fields to observe the topological properties of BICs from the polarization-resolved transmission spectra. The detail is given in Appendix B. Based on Eq. (6), Figs. 6(b) and 6(d) give the results of corresponding far-field polarization vectors by extracting the polarization-resolved transmission spectra, which are consistent with the calculated results from the eigenfields. It should be pointed out that the intervals between far-field polarization vectors look larger in comparison to the calculated results from the eigenfields because of a relatively larger wave vector extraction interval. In a word, the transmission spectra extraction method provides us with a very feasible way to experimentally observe the topological features of BICs.
Figure 6.Calculated polarization vectors around BICs in momentum space based on the eigenfield extraction method for (a) and (c) . (b), (d) Corresponding results based on the transmission spectra extraction method.
Now we show that a designed accidental quasi-BIC can be used for highly efficient second harmonic generation (SHG). The schematic of the proposed structure is given in Fig. 7(a). The geometric parameters of the bilayer grating including the lattice constant, height, width, and interlayer distance are , , , and , respectively. Here the nonlinear material is selected to be as it has large second-order nonlinear susceptibilities, and it is highly transparent from the near-infrared to near-ultraviolet region [57–59]. is an anisotropy material with a diagonal refractive index distribution of diagonal (, , ,) for the optical axis along the direction. As shown in Fig. 7(a), is along the direction, and is along the or direction. In our calculation, we suppose that and , which are obtained in the experiment [60]. According to the formation condition of BIC, one can determine the position of BIC by designing suitable interlayer distance. For instance, when the interlayer distance and , BIC can form at the incident angle . Then, we calculate the reflectance spectra of the structure at different incident angles, as shown in Fig. 7(b). It is seen that becomes a BIC with vanishing line width at . In the case of , the reflectance spectra exhibit dual asymmetric Fano line shapes, which correspond to and . We focus on that corresponds to quasi-BIC, and the corresponding electric field distributions at the cross section () and the cross section () of the unit cell for TM wave are shown in Fig. 7(c). One can see that the electric fields are highly localized inside the structure. The intensity of generated second harmonic light strongly depends on the intensity of the confined electric field within the structure. Owing to its large mode profile volume in bilayer grating when compared with other photonic structures [57–62], a highly efficient SHG would be achieved.
Figure 7.Schematic of the bilayer grating structure for highly efficient SHG. (b) Reflectance spectra of the structure at different incident angles for TM polarization. (c) Electric field distributions at the cross section () and the cross section () at the wavelength of quasi-BIC at . (d) Calculated reflectance and SHG conversion efficiency versus the wavelength of pumping light at . (e) Dependence of the SHG conversion efficiency on the incident angle. (f) Dependence of the SHG conversion efficiency on the interlayer distance at .
In general, SHG in photonic structure can be characterized as [63] In Eq. (7), denotes tensor of second-order nonlinear susceptibility, is the local electric field inside structure, and is the volume of a unit cell. Next, we calculate the nonlinear efficiency enhanced by the quasi-BIC based on the second-order polarization density () and the electric field of the pumping light () in as given by Herein, the nonlinear coefficients are , , and [60,64], respectively. The SHG conversion efficiency can be written as . Figure 7(d) shows the calculated reflectance and SHG conversion efficiency versus the wavelength of pumping light at . Assisted by quasi-BIC, the SHG conversion efficiency reaches 2% under pumping intensity . In addition, we calculate the dependence of the SHG conversion efficiency on the incident angle, as shown in Fig. 7(e). When , the SHG conversion efficiency is only 0.02%. As gradually approaches 8° (BIC condition), the SHG conversion efficiency increases significantly. When , the SHG conversion efficiency reaches 57.4%. Similarly, we calculate the dependence of the SHG conversion efficiency on the interlayer distance at , as shown in Fig. 7(f). As the interlayer distance decreases from 776 to 736 nm (approaching the BIC condition at ), the SHG conversion efficiency rapidly increases from 0.02% to 61.5%. Overall, a highly efficient SHG can be achieved in a wide parameter space, owing to the high factor and large mode profile volume of the designed quasi-BIC.
4. CONCLUSION
In conclusion, an accurately designed accidental BIC in a coupled-resonators system consisting of the bilayer grating is theoretically and experimentally investigated. We show that the position of the BIC can be arbitrarily controlled in momentum space by changing the interlayer distance between the gratings to tune the propagation phase shift related with the wave vector. Besides, we propose a general method for extracting the polarization vector fields to observe the topological properties of BICs. As an example of an application, the highly efficient SHG assisted by the quasi-BIC is also given. Besides highly efficient SHG, these freely designed BICs in momentum space would be very useful for the design of high-efficiency filters, ultrasensitive sensors, and so on.
APPENDIX A: FITTING REFLECTANCE SPECTRA BY THE SINGLE RESONATOR MODEL
The optical response of single grating can be described by the single resonator model (SRM) around the angular frequency of the guided mode resonance (GMR). Figure 8 shows the calculated and fitted reflectance spectra by SRM.
Figure 8.Reflectance spectrum of the single grating for TM polarization at . Red solid line represents the calculated reflectance spectra. Blue circle denotes the fitting reflectance spectrum based on SRM.
APPENDIX B: EXTRACTION OF POLARIZATION VECTOR FIELDS FROM TRANSMISSION SPECTRA
We can use the polarization-resolved transmission spectra to extract the polarization vector fields of the band of interest.
Here we consider a system with two-fold in-plane rotational symmetry and mirror symmetry , as illustrated in Fig. 9. Under these conditions the column vectors and describing the incoming and outgoing electric field vectors can be written as , , where subscripts and denote the TE and TM polarizations, respectively, and the superscripts and denote the waves in the upper and lower half-spaces with respect to the structure. Considering TM polarization incidence from upper half-space, the incoming electric field vector can be expressed as The corresponding outgoing electric field vector can be written as where is the scattering matrix of the system. Generally, can be decomposed into two parts: , where and describe the non-resonant process and resonant process for scattering, respectively. For a non-resonant system, can be written as while a resonant system has a scattering matrix that can be expressed as One can clearly see that the off-diagonal blocks represent individual contributions from resonance. Substituting Eq. (B4) into Eq. (B2) produces We only consider the trsnsmission spectra, so can be simplified as Here represents the outgoing electric field vectors in the lower half-space of the structure. Considering the effect of analyzers: where is the unit vector of the polarization analysis along the , the intensity received by the receiver is Normalized by , the transmittance of system for TM polarization incidence can be written as If we adjust along the , , the corresponding transmittance is , , respectively. In general, Jones vectors can be defined by two orthogonal polarization vectors. For convenience, we choose and as basis, and the corresponding Stokes parameters can be written as where “” denotes complex conjugate. It is noted that the expression above represents the polarization vectors contributed by direct process and resonance. As a result, represent the polarization vectors of non-eigenstates. Based on Eqs. (B3) and (B4), the contribution from the direct process to getting polarization vectors of eigenstates should be subtracted. Thus, the Stokes parameters can be defined as Here is the coefficient of transmission converted into the polarization for the -polarized incident light, and similarly for the other elements. and can be extracted from transmission spectra with magnitude and phase, and for the direct transmission process is formed by fitting the background in the transmission spectra to the transmission coefficients through a uniform slab with the same thickness and with an effective dielectric constant.
Figure 9.Schematic of a system with two-fold in-plane rotational symmetry and mirror-symmetry along .