Chinese Journal of Lasers, Volume. 13, Issue 1, 52(1986)
A microcomputer-controlled double-probe system measuring electron temperature of multi-kilowatt CW CO2 lasers
A microcomputer-controlled double-probe system and the software for computing the electron temperature from the V-I curve measured with this system have been developed. At different discharge currents, gas pressures, ingradients of gas mixture and probe position of the 2kW CW CO2 laser, the measured average electron temperature and electron density are in the range of (1.7-3.2)eV and (0.62-1.36) ×1011cm-3 respectively. The E/N is about 2.0 × 10-16 V cm2.
Get Citation
Copy Citation Text
Li Tongnin, Liu Donghua, Li Zaiguang, Qi Qinian. A microcomputer-controlled double-probe system measuring electron temperature of multi-kilowatt CW CO2 lasers[J]. Chinese Journal of Lasers, 1986, 13(1): 52