    The equi-luminance of color stimulus in normal subjects is characterized by L-cone and M-cone activation in retina. For the protanopes and deuternopes, only the activations of one relevant remaining cone type should be considered. The equi-luminance turning curve was established for the recorded visual evoked potentials (VEPs) of the luminance changes of the red and green color stimulus, and the position of the equi-luminance was used to define the kind and degree of color vision deficiencies. In the test of 47 volunteers we got the VEP traces and the equi-luminance turning curves, which was in accordance with the judgment by the pseudoisochromatic plate used in clinic. The method fulfills the objective and quantitative requirements in color vision deficiencies test.