NUCLEAR TECHNIQUES, Volume. 47, Issue 8, 080202(2024)

Monte Carlo simulation analysis of X-ray density logging shields

Rui LIU1,2, Huawei YU1,2、*, Qian ZHU1,2, Aizhong YUE3, Hu WANG3, Chaozhuo LIU4, Qianwen ZHANG1,2, Shu YANG1,2, Linke ZHU1,2, and Xiaolei ZHANG3
Author Affiliations
  • 1(National Key Laboratory of Deep Oil and Gas, China University of Petroleum (East China), Qingdao 266580, China)
  • 2(School of Geosciences, China University of Petroleum (East China), Qingdao 266580, China)
  • 3Well Logging Technology Research Institute of China Petroleum Group Well Logging Co., Ltd., Xi'an 710077, China
  • 4School of Science, China University of Petroleum (East China), Qingdao 266580, China
  • show less

    Background

    The use of controlled X-ray sources instead of 137Cs radioactive sources in density logging has become a new trend. The intensity of the X-ray source is substantially influenced by the high voltage on the target substrate, and the density measurement uncertainty can be maintained at 0.01 g·cm-3 when the high voltage is 350 kV.

    Purpose

    This study aims to analyze the parameters of the shielding material and thickness suitable for the 350 kV high-voltage X-ray density logging instrument.

    Methods

    The Monte Carlo method was used to analyze the energy spectrum and counting rate of X-rays passing through different materials and thicknesses. By comparing the correlation between the 0~0.15 MeV and 0.15~0.35 MeV energy windows, the reasons for the difference between the X-ray attenuation and detector count rate in different energy windows were determined. In addition, combined with the actual instrument model construction of the four-detector X-ray density logging instrument, the influence of the three parts of particles on the detector was primarily considered. The placement mode and optimal thickness of each part of the shield for detectors were analyzed and designed using Monte Carlo N-particle (MCNP) simulation.

    Results

    The simulation results show that the attenuation of X-rays in high- and low-energy windows increases with increase of atomic number and thickness of shielding materials. When tungsten nickel iron alloy is selected as the shielding material for the four-detector X-ray density logging instrument model, the suitable thickness of the shield between the base and the near-source detector is 1.75 cm. Meanwhile, to maintain the high voltage of X-ray generator at 350 kV, a shield layer with a thickness of 0.2 cm is placed between each detector, and a shield layer with a thickness of 0.35 cm is added to the back of the detector.

    Conclusions

    This study provides the design theory and key parameters for shielding materials and structures in the development of X-ray density logging tool.

    Keywords
    Tools

    Get Citation

    Copy Citation Text

    Rui LIU, Huawei YU, Qian ZHU, Aizhong YUE, Hu WANG, Chaozhuo LIU, Qianwen ZHANG, Shu YANG, Linke ZHU, Xiaolei ZHANG. Monte Carlo simulation analysis of X-ray density logging shields[J]. NUCLEAR TECHNIQUES, 2024, 47(8): 080202

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: ACCELERATOR, RAY TECHNOLOGY AND APPLICATIONS

    Received: Sep. 4, 2023

    Accepted: --

    Published Online: Sep. 23, 2024

    The Author Email: YU Huawei (于华伟)

    DOI:10.11889/j.0253-3219.2024.hjs.47.080202