Chinese Journal of Lasers, Volume. 43, Issue 2, 208003(2016)
Multi-Beams Time-Synchronization Measurement for Intertial Confinement Fusion Laser Facility
A method measuring timing synchronization of multi-beams laser for intertial confinement fusion (ICF) facility is proposed. Firstly, the time interval of reference laser beam arriving criterion point and target point is measured. Secondly, the time interval of reference laser beam arriving criterion point and measured laser beam arriving target point is measured, the D- value between these two intervals stand for the time synchronization difference between reference beam and measured beam arriving the same target point. The analysis shows that the precision of this method is 25.2 ps.The measurement technology is simple and efficient, and it has been successfully applied in the synchronization measurement of ICF laser facility.
Get Citation
Copy Citation Text
Zhang Bo, Peng Zhitao, Lü Jiakun, Sun Zhihong, Dong Jun, Lu Zongui. Multi-Beams Time-Synchronization Measurement for Intertial Confinement Fusion Laser Facility[J]. Chinese Journal of Lasers, 2016, 43(2): 208003
Category: measurement and metrology
Received: Jul. 8, 2015
Accepted: --
Published Online: Jan. 25, 2016
The Author Email: Zhang Bo (zhangbo19880331@sina.com)