The role of dual-energy CT virtual monoenergetic imaging in eliminating artifacts caused by metallic clips in early gastric cancer

LI Huanhuan1, LIU Zhuang1, CHEN Chao1, WANG Lili2, and GU Yajia1、*
Author Affiliations
  • 1Department of Radiological Diagnosis, Fudan University Shanghai Cancer Center, Shanghai 200032, China
  • 2Department of Nuclear Medicine, Shuguang Hospital, Shanghai University of Traditional Chinese Medicine, Shanghai 201203, China
  • show less

    ObjectiveTo evaluate the image quality of abdominal dual-energy CT virtual monoenergetic imaging (VMI) in patients with early gastric cancer using titanium alloy clips and assess its effectiveness on reducing metal artifacts.MethodsA retrospective study was conducted, including 31 patients with gastric cancer who underwent abdominal dual-energy CT scans with titanium clips inserted in the gastric cavity. Each scan was reconstructed into mixed images (simulated 120 kVp CT) and VMIs with energy levels ranging from 40 keV to 140 keV. Metal artifacts were quantitatively evaluated by measuring the noise values in the lesion and perigastric regions. The contrast-noise ratio (CNR) of the lesion and the corresponding liver tissue was calculated to assess the image quality. Two radiologists independently evaluated the images, considering overall quality, artifact severity, lesion conspicuity, perigastric clarity, and vascular contrast.ResultsQuantitative analysis revealed that metal artifacts in both the lesion and perigastric regions decreased as the energy level increased. VMIs at 80-140 keV (lesion site) and 90-140 keV (perigastric space) showed significantly fewer artifacts compared to mixed images (P<0.05). The CNR of lesions remained stable across VMIs at 50-140 keV, while the CNR of normal liver tissue decreased significantly with increasing energy (P<0.05). In the subjective assessment, VMIs at 80-140 keV had higher artifact scores than mixed images (P<0.05). VMIs at 70-90 keV provided better lesion conspicuity and perigastric clarity, although vascular contrast decreased significantly with increasing energy (P<0.05). VMIs at 70-90 keV showed better overall quality (P<0.05), though not significantly different from mixed images.ConclusionsVMIs at 80 keV and 90 keV improve the visibility of lesions and perigastric regions affected by metallic clips, which combined with mixed images can enhance radiologists' diagnostic accuracy.

    Tools

    Get Citation

    Copy Citation Text

    LI Huanhuan, LIU Zhuang, CHEN Chao, WANG Lili, GU Yajia. The role of dual-energy CT virtual monoenergetic imaging in eliminating artifacts caused by metallic clips in early gastric cancer[J]. Chinese Journal Of Clinical Medicine, 2025, 32(3): 376

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category:

    Received: Aug. 24, 2024

    Accepted: Aug. 22, 2025

    Published Online: Aug. 22, 2025

    The Author Email: GU Yajia (cjr.guyajia@vip.163.com)

    DOI:10.12025/j.issn.1008-6358.2025.20240932

    Topics