Acta Optica Sinica, Volume. 40, Issue 10, 1032001(2020)

Study on Pulse-Dilation X-Ray Diodes

Wenyong Fu1,2, Houzhi Cai1, Dong Wang1, Yunfei Lei1, Junkun Huang1, Yong Wang1, Pokun Deng1, Jinghua Long1、*, and Jinyuan Liu1
Author Affiliations
  • 1College of Physics and Optoelectronic Engineering, Shenzhen University, Shenzhen, Guangdong 518060, China
  • 2College of Computer and Information Engineering, Nanyang Institute of Technology, Nanyang, Henan 473500, China
  • show less

    A pulse-dilation X-ray diodes (XRD) is developed and also tested using a femtosecond laser. A time-dependent ramp waveform is applied to a photocathode (PC) to introduce a time-dependent electric field between PC and mesh. This electric field leads to an axial speed dispersion of the photoelectron signal. The electrons generated earlier move faster than those later. The photoelectrons transiting a drift region are stretched before reaching a microchannel plate (MCP), and are then amplified and read out with a digital oscilloscope. The detector's time response is enhanced by 11 times with the usage of pulse-dilation technique.

    Tools

    Get Citation

    Copy Citation Text

    Wenyong Fu, Houzhi Cai, Dong Wang, Yunfei Lei, Junkun Huang, Yong Wang, Pokun Deng, Jinghua Long, Jinyuan Liu. Study on Pulse-Dilation X-Ray Diodes[J]. Acta Optica Sinica, 2020, 40(10): 1032001

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Ultrafast Optics

    Received: Nov. 12, 2019

    Accepted: Feb. 27, 2020

    Published Online: Apr. 28, 2020

    The Author Email: Long Jinghua (jhlong@szu.edu.cn)

    DOI:10.3788/AOS202040.1032001